CARE & USE/INSTALLATION
|
16 17
|
CARE & USE/INSTALLATION
Never run flex hose behind the firebox, run
the hose at an angle, straight down, or out of
the back.
GAS CONNECTIONS ...continued
Insert the regulator inlet into the cylinder valve and turn the
black coupler clockwise until the coupler is hand tight. Do
not over-tighten this connection.
To disconnect the coupler, first make sure the main cylinder
valve is turned off. Grasp the coupler and turn counter
clockwise. The inlet will then disengage.
Always leak-test the connection after refilling or exchanging
LP cylinders. (See INDEX: “Leak Test” for further details.)
GAS LINE PURGING
You should purge the gas line of air before attempting to
light the grill.
Make sure all grill controls are in the “OFF” position.
Slowly turn on the main gas supply.
Push in the rotisserie knob and confirm that the igniter
is glowing. It is furthest from the fuel source and will
completely purge the lines. It will take several seconds for
the burner to light.
Hold the knob ON for about 20 seconds to allow the air
in the system to purge and the burner to light
Wait at least 5 minutes after shutting off the control
before attempting to light the burners.
NG AND BULK PROPANE CART INSTALLATION
Shut off the gas supply at the main valve.
Disconnect all plumbing (if already attached) from the grill
and the gas supply valve.
Remove all the fittings from the grill manifold.
Connect the gas supply to the grill as shown in the
diagram on this page for your gas type.
Turn the gas supply on and leak test all connections. (See
INDEX: “Leak Test” for further details.)
GAS CONVERSION KITS
Gas conversion kits are available from Lynx Grills to
allow the grill to operate on either Natural gas or
LPG. These kits should be installed by a qualified
technician or certified plumber.
The kits come with complete installation instructions.
These instructions should be read completely and
fully understood before installing the conversion kit.
NG AND BULK LP BUILT-IN INSTALLATION
Shut off the gas supply at the main valve.
If connecting to a bulk propane tank, disconnect the brass
elbow, hose and regulator from the grill.
Remove all the fittings from the grill manifold.
Connect the gas supply to the grill as shown in the
diagram on this page.
Turn the gas supply on and leak test all connections.
(See INDEX: “Leak Test” for further details.)
LP CONVERSION KIT
NG CONVERSION KIT
GAS CONNECTIONS ...continued
Inline
Regulator
P/N 30781
Grill Manifold
1/2” MIP
Fitting
Flexible Gas Line to Inlet
1/2” Close
Nipple
1/2” FIP
Street
Elbow
Regulator
P/N 13053
Grill Manifold with Brass Elbow
To Propane Tank
Angle At Least
20˚ From Horizon
Side Burner Installation
Inline Regulator
P/N 30781
1/2” MxF
Street
Elbow
Angle At Least
20˚ From Horizon
Grill Manifold
1/2” MIP
Fitting
Flexible Gas Line to Inlet
LP BOTTLE CART INSTALLATION
Shut off the gas supply at the main valve.
Connect the gas supply to the grill as shown in the
diagram on this page for your gas type.
Turn the gas supply on and leak test all connections. (See
INDEX: “Leak Test” for further details.)
1/2” Close
Nipple
Angle At Least
20˚ From Horizon
Grill Manifold
1/2” MIP
Fitting
Flexible Gas Line
to Side Burner
Flexible Gas
Line
To Propane Tank
1/2” FIP T Fitting
1/2” MxF
Fitting
1/2” Close
Nipple
Angle At Least
20˚ From Horizon
Grill Manifold
1/2” MIP
Fitting
Flexible Gas Line
to Side Burner
Flexible Gas
Line
To Propane Tank
1/2” FIP T Fitting
Inline Regulator
P/N 30781
1/2” MIP
Fitting
Flexible Gas Line
to Inlet
1/2” MxF
Fitting
Loading ...
Loading ...
Loading ...