18
Cleaningmetalgreaselters
Theltersmustbecleanedevery2months
ofoperation,ormorefrequentlyforparticu-
larly heavy usage, and can be washed in a
dishwasher.
• RemovetheFiltersoneatatime,pushing
themtowardsthebackoftheunitandatthe
same time pulling downward.
• Wash the Filters without bending them, and
leave them to dry completely before replac-
ing.(Ifthesurfaceofthelterchangescolour
as time goes by, this will have absolutely no
effectontheefciencyofthelteritself.)
• Replace, taking care to ensure that the
handle faces forwards.
• No water canbe present in ltersbefore
installingbackinhood.
Replacing Activated Charcoal Filter
Thelterisnotwashableandcannotberegener-
ated, and must be replaced approximately every 4
monthsofoperation,ormorefrequentlyforparticu-
larly heavy usage.
• RemovetheFiltersoneatatime,pushingthem
towardsthebackoftheunitandatthesametime
pulling downward.
• Removethesaturatedcharcoallterbyreleasing
thexinghooks.
• Fitthenewlterandfastenitinitscorrectposition.
• Replace,takingcaretoensurethatthehandle
faces forwards. "When used in recirculation
mode,toReducetheRiskofFireandShock
useonlyconversionkitModelFILTER2".
Lighting Unit
• LED lights must be replaced by Faber factory authorized
service.