Installation
*INSTALLATION*
27
a
Extraction mode
b
Recirculation
c
Air vent positioned at the top for recirculation
de
Installation area (only d is required for recirculation operation). Wall or ceiling
area for the ducting cutout and for the electrical outlet. For recirculation
operation, only an electrical outlet needs to be installed.
Exhaust connection 6" (150mm)
Distance between cooktop and ventilation hood (S)
Provided a larger distance is not given by the manufacturer of the cooktop, follow
the minimum safety distances between a cooktop and the bottom of the hood.
Please also observe the information contained in the “IMPORTANT SAFETY
INSTRUCTIONS” section.
Minimum distance S
Cooking appliance Miele
appliance
Non-Miele
appliance
Electric Cooktops 24" (610mm)
Electric Barbeques and Fryers 26" (660mm)
Multiburner Gas Cooktops
43,000 BTU/hr (12.6kW),
no burner > 15,000 BTU/hr (4.5 kW).
26" (660mm) 30" (760mm)
Multiburner Gas Cooktops
73,800 BTU/hr (21.6kW),
no burner > 16,500 BTU/hr (4.8 kW)
30" (760mm)
Multiburner Gas Cooktops
> 73,800 BTU/hr (21.6kW),
or one of the burners > 16,500 BTU/hr (4.8 kW)
Not possible
Single Burner Gas Cooktops
20,500 BTU/hr (6 kW)
26" (660mm) 30" (760mm)
Single Burner Gas Cooktops
> 20,500 BTU/hr (6 kW)
27,600 BTU/hr (8.1 kW)
30" (760mm)
Single Burner Gas Cooktops
> 27,600 BTU/hr (8.1 kW)
Not possible