For MAST305DFMXE. Also, The document are for others Bertazzoni models: MAST305DFMBIE, MAST305DFMNEE, MAST365DFMBIE, MAST365DFMNEE, MAST365DFMXE, MAST366DFSXT, MAST486GDFSXT, MAST486GDFMXE, HERT366DFSX, HERT366DFSAV, HERT366DFSNE, HERT486GDFSX, HERT486GDFSAV, HERT486GDFSNE, PROF304DFSART, PROF304DFSBIT, PROF304DFSGIT, PROF304DFSNET, PROF304DFSROT, PROF304DFSXT, PROF366DFSAR, T PROF366DFSBIT, PROF366DFSGIT, PROF366DFSNET, PROF366DFSROT, PROF366DFSXT, PROF486GDFSART, PROF486GDFSBIT, PROF486GDFSGIT, PROF486GDFSNET, PROF486GDFSROT, PROF486GDFSXT

PDF File Manual, 46 pages, Read Online | Download pdf file

MAST305DFMXE photo
Loading ...
Loading ...
Loading ...
15
/ Gas connection
PRESSURE REGULATOR
Since service pressure may uctuate with local
demand, every gas cooking appliance must be
equipped with a pressure regulator on the inco-
ming service line for safe and effi cient operation.
The pressure regulator shipped with the applian-
ce has two female threads ½” NPT. The regulator
shall be installed properly in order to be accessible
when the appliance is installed in its fi nal position.
Manifold pressure should be checked with a ma-
nometer and comply with the values indicated be-
low:
Natural gas 4.0” iwc.
LP/Propane 10.0” iwc.
Incoming line pressure upstream from the regula-
tor must be 1” iwc. higher than the manifold pres-
sure in order to check the regulator.
The regulator used on this range can withstand a
maximum input pressure of 1/2 PSI (13,8” w.c. or
3,5 kPa) If the line pressure exceeds that amount,
a stepdown regulator is required.
The appliance, its individual shut-off valve, and
the pressure regulator must be disconnected from
the gas line during any pressure testing of that sy-
stem at pressures in excess of 1/2 PSI (13,8” iwc
or 3,5 kPa).
The individuaL manual shut-off valve must be in
the OFF position during any pressure testing of
the gas supply piping system at test pressures
equal to or less than 1/2 PSI (13,8” iwc or 3,5 kPa).
Warning
Before carrying out any servicing operation di-
sconnect the appliance from gas and electric
supply and extra appliance from nal installation
place in order to have access to the appliance for
proper servicing intervention.