Loading ...
Loading ...
Loading ...
9
INSTALLATION
WARNING: NEVER OPERATE THE AIR CONDITIONER
WITHOUT THE AIR FILTER
AIR FILTERS
Silvershield Pre-filter
This portable air conditioner is equipped with a
Silvershield pre-filter, which removes large particles such as
dust, pet hair and dander. This pre-filter can be removed for
cleaning by pulling the filter frame back and out. This pre-filter
washable and does not need to be replaced.
3MAntimicrobial High Air Flow Filter
This portable air conditioner comes with the 3MAntimicrobial
High Air Flow Filter which is designed to remove particles such
as dust, pet hair and dander, antimicrobial agent helps inhibit
the growth of mold and mildew, and the micro-structured elec-
trostatically charged filtration media traps and retains particles.
The 3M Filter is pre-installed.
Note: The 3M Filter should be replaced every 2-3 months de-
pending on usage. Please contact info@whynter.com for retail
sales information.
WATER DRAINAGE
The dehumidifying capacity of this unit is 61 pints per day.
The patented self-evaporating function of the ARC-126MD
unit fully exhausts all condensation automatically in most en-
vironments when humidity is less than 70%. Areas with more
than 70% humidity, the self-evaporating function can still ex-
haust about 98% of the moisture and the remaining 2% of
moisture will be collected in the water tank of the air condi-
tioner.
When the water reservoir reaches its maximum level, the unit
will beep 8 times and the digital display will show P1. When
the unit displays P1, all operation modes will be disabled
temporarily, while the fan continuously running. The P1 code
will disappear when the water is completely drained.
Manual drainage (Fig. 1a)
Carefully move the unit to a drain location, remove the bot-
tom drain plug and let the water drain. Replace the drain plug
and plug in unit to resume operation.
Continuous drainage (Fig. 1b)
Remove the upper drain plug from the back of the unit and
install the drain hose. Place the open end of the hose to a
drain area. This method is recommended if uninterrupted op-
eration is desired.
3M Filter
Silvershield FIlter
Remove bottom
drain plug for
Manual Drainage
Attach drain hose
for Continuous
Drainage
Fig. 1a
Fig. 1b
Loading ...
Loading ...
Loading ...