Leak Tesng Instrucons
WARNING! A leak test must be performed annually and each me a cylinder is hooked up or if a
part of the gas system is replaced.
WARNING! Never use an open ame to check for gas leaks. Be certain no sparks or open ames
are in the area while you check for leaks. Sparks or open ames will result in a re or explosion,
damage to property, serious bodily injury, or death.
Leak tesng:
This must be done before inial use, annually, and whenever any gas components are
replaced or serviced. Do not smoke while performing this test, and remove all sources of ignion. See Leak
Tesng Diagram for areas to check. Turn all burner controls to the o posion. Turn gas supply valve on.
Brush a half-and-half soluon of liquid soap and water onto all joints and connecons of the regulator,
hose, manifolds and valves.
Bubbles will indicate a gas leak. Either ghten the loose joint or have the part replaced with one
recommended by the Napoleon Customer Soluons department and have the grill inspected by a cered
gas installer.
If the leak cannot be stopped, immediately shut o the gas supply, disconnect it, and have the grill
inspected by a cered gas installer or dealer. Do not use the grill unl the leak has been corrected.
STOP
!
!
WARNING!
• The installaon must be performed by a licensed gas er, and all connecons must be leak
tested before operang the grill.
• Do not route hose underneath the drip pan.
• Do not route hose between boom shelf space and back panel.
• Do not route hose over top of rear panel.
• Ensure all hose connecons are ghtened using two wrenches. Do not use Teon tape or pipe
dope on any hose connecon.
• Ensure the hose does not contact any high temperature surfaces or it may melt and leak causing a
re.
• Leak test all the connecons using a soap and water soluon as per the leak tesng instrucons
found in the manual.
• The outdoor cooking gas appliance and its individual shuto valve must be disconnected from the
gas supply piping system during any pressure tesng of that system at test pressures in excess of
0.5 psi (3.5 kPa).
• The outdoor cooking gas appliance must be isolated from the gas supply piping system by closing
its individual manual shuto valve during any pressure tesng of the gas supply piping system at
test pressures equal to or less than 1/2 psi (3.5 kPa).