Leak Tesng Instrucons
WARNING! A leak test must be performed annually and each me a cylinder is hooked up or if a
part of the gas system is replaced.
WARNING! Never use an open ame to check for gas leaks. Be certain no sparks or open ames
are in the area while you check for leaks. Sparks or open ames will result in a re or explosion,
damage to property, serious bodily injury, or death.
Leak tesng:
This must be done before inial use, annually, and whenever any gas components are
replaced or serviced. Do not smoke while performing this test, and remove all sources of ignion. See Leak
Tesng Diagram for areas to check. Turn all burner controls to the o posion. Turn gas supply valve on.
Brush a half-and-half soluon of liquid soap and water onto all joints and connecons of the regulator,
hose, manifolds and valves.
Bubbles will indicate a gas leak. Either ghten the loose joint or have the part replaced with one
recommended by the Napoleon Customer Soluons department and have the grill inspected by a cered
gas installer.
If the leak cannot be stopped, immediately shut o the gas supply, disconnect it, and have the grill
inspected by a cered gas installer or dealer. Do not use the grill unl the leak has been corrected.
STOP
!
!
WARNING!
The installaon must be performed by a licensed gas er, and all connecons must be leak
tested before operang the grill.
Do not route hose underneath the drip pan.
Do not route hose between boom shelf space and back panel.
Do not route hose over top of rear panel.
Ensure all hose connecons are ghtened using two wrenches. Do not use Teon tape or pipe
dope on any hose connecon.
Ensure the hose does not contact any high temperature surfaces or it may melt and leak causing a
re.
Leak test all the connecons using a soap and water soluon as per the leak tesng instrucons
found in the manual.
The outdoor cooking gas appliance and its individual shuto valve must be disconnected from the
gas supply piping system during any pressure tesng of that system at test pressures in excess of
0.5 psi (3.5 kPa).
The outdoor cooking gas appliance must be isolated from the gas supply piping system by closing
its individual manual shuto valve during any pressure tesng of the gas supply piping system at
test pressures equal to or less than 1/2 psi (3.5 kPa).