Back View
Cabinet Dimensions
IMPORTANT: Minimum distance “X” : 24" (61�0 cm) to electric
cooking surface and 30" (76�2 cm) to gas cooking surface�
Suggested maximum distance “X” : 36" (91�4 cm)�
Venting Requirements
Vent system must terminate to the outdoors�
Do not terminate the vent system in an attic or other
enclosed area�
Do not use a 4" (10�2 cm) laundry-type wall cap�
Use metal vent only� Rigid metal vent is recommended�
The length of vent system and number of elbows should be
kept to a minimum to provide efcient performance�
For the most efficient and quiet operation:
Use no more than three 90° elbows�
Make sure there is a minimum of 24" (61�0 cm) of straight
vent between the elbows if more than one elbow is used�
Do not install two elbows together
Use clamps or duct tape to seal all joints in the vent system�
The vent system must have a damper� If roof or wall cap has
a damper, do not use damper supplied with the range hood�
Use caulking to seal exterior wall or roof opening around
thecap�
The size of the vent should be uniform�
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold air ow and a thermal break should be installed
to minimize conduction of outside temperatures as part of the
vent system� The damper should be on the cold air side of the
thermal break�
The break should be as close as possible to where the vent
system enters the heated portion of the house�
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specied CFM of air
movement� The specied CFM varies from locale to locale�
Consult your HVAC professional for specic requirements in
yourarea�
Venting Methods
This canopy hood is factory set for venting through the roof
orwall�
A 3
1
/
4
" x 10" (8�3 x 25�4 cm) rectangular vent system is needed
for installation (not included)� The hood exhaust opening is
3
1
/
4
"x 10" (8�3 x 25�4 cm)� Vent system can terminate either
through the roof or wall� To vent out of the top of the range hood
and through a wall, a 90° elbow is needed� See “Install Range
Hood” section for details for installing the damper
NOTE: Flexible vent is not recommended� Flexible vent
creates back pressure and air turbulence that gently reduce
performance�
1¹⁄₈"
(2.9 cm)
7" (17.8 cm): 30" (76.2 cm) models
9⁷⁄₈" (25.0 cm): 36" (91.4 cm) models
Wiring knockout
7⁷⁄₈"
(20.0 cm)
30" (76.2 cm) models: 12¼" (31.1 cm)
36" (91.4 cm) models: 15" (38.1 cm)
12³⁄₁₆" (31.0 cm)
⁵⁄₈"
(1.6 cm)
A. For installations with canopy
only. 70" (177.8 cm) minimum
above electric cooking surface.
76" (193.0 cm) minimum above
gas cooking surface.
B. For installations with optional
duct cover. 82" (208.3 cm)
minimum above electric
cooking surface. 88”
(223.5 cm) minimum above
gas cooking surface.
13" (33.0 cm)
18"
(45.7 cm) min.
clearance upper
cabinet
to countertop
36" (91.4 cm)
countertop height
30" (76.2 cm) or 36" (91.4 cm)
cabinet opening width
(If installed between cabinets)
A
B
X
Bottom of canopy
to cooking surface
Min. cabinet
opening width
Duct cover (if used)
Canopy