27
IMPORTANT: ONLY FOR EXTERNAL BLOWER INSTALLATION
13
WIRING BOX 2 CONNECTION
(Remote Blower Wiring Box)
Connect the cable from the Remote Blower with the two wires inside the Wiring Box 2 by twist-on type
wire connector and matching the color:
- Black with Black
- White with White
Connect the green ground wire from remote blower to green ground screw.
Replace the eld wiring compartment cover.
Check the Wiring Diagram.
A. Remote Blower power supply cable.
B. Black wires.
C. UL listed wire connectors.
D. White wires.
E. Internal Hood Cable.
F. Green ground screw.
1
2
A
E
D
C
B
F