EXHAUST LENGTH CALCULATION
ALTERNATE EXHAUST DIRECTIONS
IF YOUR DRYER COMES WITH REAR EXHAUST,
TO CHANGE TO SIDE OR DOWN EXHAUST:
Remove access panel at back of dryer to gain access to
internal ducts.
Disconnect duct exhaust from blower housing (remove tape
securing duct).
FOR SIDE EXHAUST:
Remove desired knockout plate
(either right or left side).
Cut a 115 mm (4
1
/
2
”) length of
100 mm (4”) dia. rigid duct as
shown (remove burrs from cut edge).
Attach this extension duct to
blower housing duct.
Attach a 90˚ elbow facing desired
opening.
Attach a section of 100 mm (4”)
dia. rigid duct to elbow to
protrude thru side of cabinet.
Seal all joints with duct tape.
Reinstall rear access panel.
FOR BOTTOM EXHAUST:
Remove cover plate at bottom of
dryer.
Install a 90˚ elbow.
Seal all joints with duct tape.
Reinstall rear access panel.
Place cover plate (removed from
bottom of dryer) over rear exhaust
opening.
IF YOUR DRYER COMES WITH TOP EXHAUSTING,
TO CHANGE TO SIDE OR REAR EXHAUST:
Remove rear access panel.
Disconnect retaining plate & 90˚ elbow by removing
mounting screw from the chassis & remove tape securing
elbow to blower housing.
Remove cover plate from rear access panel and place over
top exhaust opening.
FOR SIDE EXHAUST:
Remove retaining plate attached to 90˚ elbow.
Remove desired knockout plate (either right or
left side).
Cut a 115 mm (4
1
/
2
”) length of 100 mm (4”)
dia. rigid duct as shown (remove burrs from
cut edge).
Attach this extension duct to blower housing
duct.
Attach the 90˚ elbow facing desired opening.
Attach a section of 100 mm (4”) dia. rigid
duct to elbow to protude thru side of cabinet.
Seal all joints with duct tape.
Reinstall rear access panel.
FOR REAR EXHAUST:
Cut a 295 mm (11
5
/
8
”) length of 100 mm (4”)
dia. ridig duct as shown (remove burrs from
cutting edge).
Attach this extension duct to blower housing.
Seal all joints with duct tape.
Reinstall rear access panel.
Table 1: RECOMMENDED MAXIMUM LENGTH
ELECTRIC DRYERS
Weather Hood Type
Recommended
Use only for short
run installations
No. of 90˚
elbows
Rigid
Metallic
Flexible*
Rigid
Metallic
Flexible*
0
1
2
3
14 m (46 ft.)
11 m (38 ft.)
9 m (31 ft.)
7 m (24 ft.)
9 m (30 ft.)
7.5 m (25 ft.)
6 m (20 ft.)
5 m (16 ft.)
11 m (37 ft.)
9 m (30 ft.)
6.5 m (22 ft.)
4.5 m (15 ft.)
7 m (24 ft.)
6 m (20 ft.)
4 m (14 ft.)
3 m (10 ft.)
* Do not use non metallic flexible duct.
152 mm
203 mm
(8")
Bottom
knockout
Right knockout
89 mm
(3
1
/
2")
Front of dryer
Blower
Left knockout
6"
295 mm
115 mm
(11
5
/
8
")
(4
1
/
2
")
For Rear Exhaust
For Side Exhaust
Rigid
Metallic
Ducting
Cut Here
EXTENSION DUCT
NOTE: Non-metallic ducts must never be used inside dryer cabinet.