Problem solving guide
42
Other problems
Problem Possible cause and remedy
An alarm sounds. The door alarm has been activated.
Close the appliance door. The alarm will stop.
An LED indicator light is
flashing at the back of
the appliance at the
bottom near the
compressor (depending
on model).
The electronic unit for
the compressor is
equipped with an
operation and fault
diagnosis LED indicator
light.
The indicator light flashes several times every
5seconds.
A fault has occurred.
Call Miele.
The indicator light flashes regularly every
15seconds.
Not a fault. This flashing is normal.
The external walls of
the appliance feel
warm.
This is not a fault. The heat which results from the
cooling process is used to avoid the build-up of
condensation on the appliance.
The door seal is
damaged and needs to
be replaced.
No tools are required to change the door seal.
Change the door seal. A replacement is available
from Miele.
The floor of the
refrigerator is wet.
The condensate drain hole is blocked.
Clean the condensate channel and drain hole.