Procom MN100HBA

User Manual - Page 17

For MN100HBA.

PDF File Manual, 32 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
www.usaprocom.com
17200044-01B
Figure 17 - Pilot
8. To select the desired heating level, partially
press down the control knob slightly and
turn counterclockwise . Release
downward pressure on the knob while
continuing to turn until the knob locks
at the desired setting. The main burner
should light. Set control knob to the de-
sired heating position.
Note: Both HIGH and LOW are locked
positions. You must press in the control
knob before turning it from these positions.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
OPERATION
Pilot Burner
Ignitor Electrode
Thermocouple
Figure 18 - Control Knob in the OFF
Position
1. STOP! Read the safety information on
page 16.
2. Make sure equipment shutoff valve is fully
open.
3. Turn control knob clockwise to the
OFF position.
4. Wait ve (5) minutes to clear out any air.
Then smell for gas, including near the
oor. If you smell gas, STOP! Follow "B"
in the safety information on page 16. If you
do not smell gas, go to the next step.
5. Turn control knob counterclockwise
to the PILOT position. Press in control
knob for ve (5) seconds (see Figure 18).
Note: The rst time that the heater is oper-
ated after connecting the gas supply,the
control knob should be pressed for about
thirty (30) seconds. This will allow air to
bleed from the gas system. If pilot does
not stay lit, refer to Troubleshooting, pages
21 though 23. Also contact a qualied
service technician or gas supplier for
repairs. Until repairs are made, light pilot
with match.
If control knob does not pop up when
released, contact a qualified service
technician or gas supplier for repairs.
6. With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached to
the front of burner. The pilot can be
seen through the grill. If needed, keep
pressing ignitor button until pilot lights.
Note: If pilot does not stay lit, refer to
Troubleshooting, pages 22 though 24.
Also contact a qualied service technician
or gas supplier for repairs. Until repairs
are made, light pilot with match. To light
pilot with match, see Manual Lighting
Procedure, page 19.
7. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. If control
knob does not pop up when released,
contact a qualied service technician or
gas supplier for repairs.
Note: If pilot goes out, repeat steps 3
through 7. This heater has a safety inter-
lock system. Wait one (1) minute before
lighting pilot again.
8. Turn control knob counterclockwise
to desired heating level. The main burner
should light. Set control knob to any heat
level between HI and LO.
PILOT
LO
OFF
HI
Ignitor Button
Control Knob
THERMOSTAT MODELS
LIGHTING INSTRUCTIONS
Loading ...
Loading ...
Loading ...