Wolf CSO24TE/S/TH Oven

User Manual - Page 4

For CSO24TE/S/TH.

PDF File Manual, 20 pages, Read Online | Download pdf file

CSO24TE/S/TH photo
Loading ...
Loading ...
Loading ...
4
|
Wolf Customer Care 800.222.7820
Electrical
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation. Refer to the illustration below for minimum power
cord plug clearance.
Performance may be compromised if the electrical supply is
less than 240 volts.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 20 amp dedicated circuit
Receptacle NEMA 6-20R grounding-type
Power Cord 6'
(1.8 m)
SPECIFICATIONS
WARNING
ELECTRICAL SHOCK HAZARD: Plug into a grounded
3-prong outlet. Do not remove ground prong. Do not
use an adapter. Failure to follow these instructions can
result in electric shock, re, or death.
NEMA
PLUG
GROUNDED
NEMA RECEPTACLE
3"
(76)
MINIMUM CORD
CLEARANCE
NEMA 6-20R receptacle.
Power cord clearance.
Rating plate location.
RATING PLATE
Loading ...
Loading ...
Loading ...