14
Problems Causes Solutions
Excessive
vibration.
The appliance is not on a
flat, stable surface.
Put the appliance on a flat stable surface.
Volume of ingredients is
too high.
Reduce the quantity of ingredients
processed.
Error in assembling the
accessories.
Check that the bowls (E4) (F4) are
correctly assembled with the blade units
(E2) (F2) associated with them, the
coloured markers should be identical.
Leak through lid. Volume of ingredients is
too high.
Reduce the quantity of ingredients
processed.
The lid is not fitted
correctly.
Check that the seal is in place (D5) on
the lid (D6). Correctly position the lid
(D6) on the bowl (D). Lock the button
(D7).
Leak from the
bowl or acces-
sories
Incorrect positioning of the
seal on the blade unit (D1)
(E1)(F1).
Make sure that the seal is correctly
positioned, the lips of the seal should
be visible and it should not be buckled
(fig1). Handle the blade units (D1),
(E1), (F1) with care because the blades
are sharp.
The blade unit (D1)(E1)
(F1) is insufficiently or
incorrectly locked on the
bowl (D4)(E4)(F4).
Make sure that the blade unit and the
bowl are fitted together correctly be
pressing at the top of the button (D2)
(fig2c) or on the buttons (E2)(F2)
(fig5c)
The blade does
not rotate easily.
Pieces of food that are too
big or too hard.
Reduce the size or quantity of the
ingredients processed.
Add liquid to the bowl mix without
exceeding the maximum level.