Dacor DOP36M86DHS Contemporary 36" Stainless Steel Natural Gas/High Altitude Dual Fuel Steam Range

User Manual - Page 17

For DOP36M86DHS.

PDF File Manual, 37 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
17English
Installation Requirements
Gas and Electrical Service
See below for the recommended location of the gas inlet and electrical junction box/receptacle. Existing
utilities may be used if they are compatible with this range. Check local building codes for allowed gas-
valve locations.
An external manual shut-off valve must be installed between the gas inlet and range so the range's gas
supply can be turned on/off. Installation must allow access to the gas shut-off valve when the unit is in-
stalled and access to the remote circuit-breaker panel/fuse box without moving the range.
The gas-supply piping and shut-off valve, and the electrical junction box/receptacle must be located so as
not to interfere with the range when it is installed.
The junction box and gas-shut off valve must be located so the range can be pulled out for service without
being disconnected.
Model D E F G
DOP36M86D* 8 7/8" (22.5 cm) 6 5/8" (16.8 cm) 11 3/16" (28.4 cm) 24 1/4" (61.6 cm)
DOP48M86D* 5 1/2" (13.9 cm) 6 5/8" (16.8 cm) 8 1/8" (20.6 cm) 26 5/8" (67.6 cm)