User's Guide - Page 5

For MHS. Also, The document are for others LiftMaster models: MH 5011U, MHS 5011U, MT 5011U, BMT 5011U, MGJ 5011U, MJ 5011U

Loading ...
Loading ...
Loading ...
5
D14
COM INTRLK STOP
LED
OPENCLOSE
TTC
LEARN
1
LMEP1 LMEP2
234567
STOP CLOSE OPEN
R27
AUXANT
^^^^
AUXANT
AUX ANT
D14
COMINTRLK STOP
LED
OPENCLOSE
TTC
LEARN
1
LMEP1LMEP2
234567
STOP CLOSE OPEN
Press and
release the
LEARN button
(LED will light).
BASIC PROGRAMMING
TIMER DEFEAT
The TTC can be temporarily disabled by pressing a STOP button. TTC will become enabled after the next open command.
1
23
CLEAR THE TIMER-TO-CLOSE (TTC)
D14
COM INTRLK STOP
LED
OPENCLOSE
TTC
LEARN
1
LMEP1 LMEP2
234567
STOP CLOSE OPEN
R27
Press and hold
the TTC button
for 6 seconds.
D14
COM INTRLK STOP
LED
OPENCLOSE
TTC
LEARN
1
LMEP1 LMEP2
234567
STOP CLOSE OPEN
R27
Release the
TTC button
(LED will go
out). The TCC
will no longer
be active.
D14
COM INTRLK STOP
LED
OPENCLOSE
TTC
LEARN
1
LMEP1 LMEP2
234567
STOP CLOSE OPEN
R27
Press and
release the
TTC button.
D14
COM INTRLK STOP
LED
OPENCLOSE
TTC
LEARN
1
LMEP1 LMEP2
234567
STOP CLOSE OPEN
R27
AUXANT
^^^^
AUXANT
AUX ANT
D14
COMINTRLK STOP
LED
OPENCLOSE
TTC
LEARN
1
LMEP1LMEP2
234567
STOP CLOSE OPEN
Press and hold
the LEARN button
(LED will light).
D14
COM INTRLK STOP
LED
OPENCLOSE
TTC
LEARN
1
LMEP1 LMEP2
234567
STOP CLOSE OPEN
R27
Every press and release
of the STOP button
will add 5 seconds to
the Timer-to-Close.
Example: 30 second
TTC = 6 presses of the
STOP button.
D14
COM INTRLK STOP
LED
OPENCLOSE
TTC
LEARN
1
LMEP1 LMEP2
234567
STOP CLOSE OPEN
R27
Press and release
the TTC button to
exit programming
mode. The LED
will fl ash once per
5 seconds of timer
setting.
D14
COM INTRLK STOP
LED
OPENCLOSE
TTC
LEARN
1
LMEP1 LMEP2
234567
STOP CLOSE OPEN
R27
Press and
release the
TTC button.
3
D14
COM INTRLK STOP
LED
OPENCLOSE
TTC
LEARN
1
LMEP1 LMEP2
234567
STOP CLOSE OPEN
R27
AUXANT
^^^^
AUXANT
AUX ANT
D14
COMINTRLK STOP
LED
OPENCLOSE
TTC
LEARN
1
LMEP1LMEP2
234567
STOP CLOSE OPEN
Press and
release the
LEARN button
(LED will light).
TIMER-TO-CLOSE (TTC)
TO PROGRAM
Begin with door in fully closed position.
Timer-to-Close feature enables the operator to close from the open limit after a preset time, adjustable from 5 to 60 seconds. Requires
LiftMaster Monitored Entrapment Protection (LMEP) device.
12 4
1
23
TO VERIFY TIMER-TO-CLOSE (TTC) SETTING
The TTC will become active after completion of the next open cycle. NOTE: The LED does not indicate that timer is running.
D14
COM INTRLK STOP
LED
OPENCLOSE
TTC
LEARN
1
LMEP1 LMEP2
234567
STOP CLOSE OPEN
R27
Press and release the TTC button a
second time. The LED will fl ash once
per 5 seconds of timer setting.
Loading ...