Marcy NS-4080EA(C80) Onyx Elliptical Cross Trainer

User Manual - Page 18

For NS-4080EA(C80).

PDF File Manual, 30 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
18
www.puretecfitness.com
Operation guide:
confirm your Gender. The default sex is 1 (MAN).
6. The AGE will flash and you can press UP or DOWN keys to set your AGE. Press
ENTER key to confirm your AGE. The default AGE is 35.
7. Press the START/STOP key to begin body fat measurement. If the window show E
on the window, please make sure your hands are attached well on the grips or the
chest belt is touch well on your body. Then press the START/STOP key again to
begin body fat measurement.
8. After finished your measurement, the computer will show the values of BMR, BMI
and FAT PERCENT on the LCD display. Furthermore, the computer will show your
own exercise profile for your body type.
9. Press START/STOP key to begin exercise.
1. Sleep Mode:
The computer will enter the sleep mode when there is no signal input and no keys be pressed
after 4 minutes. You can press any key to wake up the computer.
2. BMI (Body Mass Index): BMI is a measure of body fat based on height and weight that applies to
both adult men and women.
3. BMR (Basal Metabolic Rate): Your Basal Metabolic Rate (BMR) shows the number of calories
your body needs to operate. This doesn’t account for any activity, it’s simply the energy needed to
sustain a heartbeat, breathing and normal body temperature. It measures the body at rest, not
sleep, at room temperature.
Error Message:
E1 (ERROR 1):
Normal state: During workout, when the monitor did not get the count signal from the gear motor
more than 4 seconds and check under successive 3 times then the LCD will show E1.
Power on state: The gear motor will return to zero automatically, when the signal of motor cannot be
detected for more than 4 seconds then the gear motor’s driver will be cut off
immediately and show the E1 on the LCD display. All the other digital and function
mark are blank, and the output signals are cut off also.
E2 (ERROR 2): When the monitor read the memory data, if the I.D. code is not correct or the memory IC
damages then the monitor will show E2 immediately at power on.
E3 (ERROR 3): After 4 seconds by start mode, the computer detects the faulty motor did not leave the
zero point then the LCD bar displays “E3”.
Technical data of the current adapter
1. Available for Input: 230V/50Hz or 60Hz Output: 6V DC/0.5~1A
2. Available for Input: 110V/50Hz or 60Hz Output: 6V DC/0.5~1A
LCD Workout Graphics
PRESET PROGRAM PROFILES:
PROGRAM 1 PROGRAM 2 PROGRAM 3
MANUAL STEPS HILL
Loading ...
Loading ...
Loading ...