INSTALLATION
Location
The air conditioner should be placed on a hard and level surface strong enough to support its weight. The unit is
equipped with caster wheels for portability. It should only be rolled on smooth, flat surfaces. Use caution when
rolling on carpet surfaces. Do not attempt to roll the unit over objects.
The air inlet and outlet should be free of any obstructions and be placed with at least 20” of clearance for efficient
air-conditioning and circulation.
Exhaust hose Installation
When using the air conditioner, the hot air from the exhaust hose must be exhausted out of the room to complete
the air exchange of the condenser. The intake hose is optional. When the unit is operating in dehumidifying or fan-
only mode, installation of the exhaust hose is optional.
Window kit Installation
Your window kit has been designed to fit most standard vertical and horizontal windows. However, it may be
necessary for you to modify the installation procedures for your window.
NOTE:
If your window opening is smaller than the minimum length of the window slider kit, the window slider kit can be cut to
fit the window opening. Never cut into the exhaust and intake hose cut-outs on the window slider kit.
If your window opening is larger than the maximum length of the window slider kit, additional material will be needed
to cover the open space such as, Plexiglas, PVC plastic, ply wood, etc. Alternately, an additional window slider kit
can be purchased to be used in combination with the included kit.
When using the window slider kit on a window or sliding door, additional security measures may be needed.
1. Expand each end of the exhaust (large) and intake (small) hoses about 6”.
2. Install the Large Exhaust Slide Locking Hose Connector to one end of the
exhaust hose (large hose) and the Large Exhaust Hose Connector with tab cut-outs
to the other end of the exhaust hose (large hose) by turning clockwise.
3. Install the Small Intake Slide Locking Hose Connector to one end of the
intake hose (small hose) and the Small Intake Hose Connector with tab cut-outs to
the other end of the intake hose
(small hose) by turning clockwise.
4. Slide each of the slide locking hose connectors onto the rear of the unit
(See illustration)
Only extend the hose to the necessary length, keeping it as short and as straight as possible. We do not recommend
extending the hose more than 9' long. If you are interested in purchasing an additional 5’ exhaust hose, please
contact [email protected] for retail sales information or visit whynter.com for a list of optional accessories.
Note: To remove the hose(s) from the unit, press the release button and slide the hose and connector out.
1. Open the window approximately 5”.
2. Adjust the length of the window slider to the same length and width of the opening of the window. Cut the window
slider if necessary to fit the length of your window.
3. Insert the fixture through the back grooved side of the window slider hose cut-out. Line up the fixture with the 4
screw holes and tighten the fixture with 4 screws from the front side of the slider panel. (Fig. 1)
4. Fit the window slider kit into the window opening and close the window to secure the window slider kit. For long
term installation, you may screw the window kit into your window frame.
5. Move the air conditioner close to the window, extend the hoses to the necessary length, keeping them as short
and as straight as possible and attach the other end of each hose to the window slider kit.
6. Align the tab cut-outs of the hose connectors to the tabs on the fixtures and snap the hose connectors to the
window slider kit.