V-Tac VT-3338 38W UVC Lamp Sensor Controller

INSTALLATION INSTRUCTION

For VT-3338.

PDF File Manual, 14 pages, Read Online | Download pdf file

VT-3338 photo
WEEE Number
: 80133970
INSTALLATION INSTRUCTION
(VT-3338)
OPERATING & SAFETY INSTRUCTION:
1. Read this instruction before using.
2. Check the local voltage before working.
3. Plug in the appliance under normal input voltage.
4. When the adapter is plugged in, the appliance display “OFF” indicating LED light is off.
5. The appliance default setting for sterilization time is 30mins. If you want to select steriliza-
tion time of 15min, 30 mins or 60mins, please press the switch for 5 seconds, it will switch
into the setup mode. Set the time as per your requirement (15mins, 30mins, 60mins). After
setting up the time, the appliance automatically switches “OFF” and restart with the set time.
6. After the lamp is switched on, the appliance will display with 10 seconds count-down before
lighting. The radar sensor function will automatically start working when the lamp is ON and if
any motion (human/animal) is detected within 10 meters, the lamp will turn OFF automatical-
ly and display “RD”. The lamp switches back into sterilization mode if no motion is detected
for 10 seconds.
7. LED light always light up during the sterilization time.
8. The appliance will automatically be turned off by the timer after the working time which
was set up previously(15mins or 30mins or 60mins), it can also be shut down by pressing
switch or pull out the plug to cut off the power supply.
9. The appliance has the remote controller featuring switch on/off functionality, and all the
above setting up operation can be operated by the remote controller.
10. When using the remote controller to operate the appliance, the LED light will blink to
remind that the remote controller is in use.
11. Humans and animals should not be near the lamp once it has been powered ON.
12. Avoid looking directly into the light. Avoid eye and skin exposure to unshielded product.
Use only in an enclosed environment which shields users from the radiation. During steriliza-
tion, human and animal must get out from the place. Absorbing too much ultraviolet light can
cause skin irritation and conjunctival damage
13. The lamp is with ozone which is an unstable toxic gas with a pungent odor and powerful
oxidizing properties. Exposure in high levels to ozone may cause harm to humans.
14. After sterilization it is advised to ventilate the place for 20-30 minutes. The lamp emits
ozone, intense exposure of which is harmful.
15. Repairs should be carried out by the manufacturer or qualified electricians ONLY. Never
remove any fixed part of the appliance to make any internal adjustment. If the supply cord of
the lamp or other part of appliance is damaged, the manufacturer or its service agent or
similarly qualified person must replace it in order to avoid a hazard.
16. Unplug the lamp before cleaning. Make sure the to clean the lamp(tube). Any dusty or
stains on the glass would affect the sterilization.
17. Do not use alcohol, gasoline or chemicals to clean the appliance. Be sure to cut off the
electricity when cleaning and repairing the appliance.
18. Make sure that your local voltage and frequency should be suitable for the lamp.
19. This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety.
20. Children should be supervised to ensure that they do not play with the appliance.
21. The appliance is for indoor use only. The appliance is not to be used in locations where
flammable vapors or explosive dust is likely to exist. Hang or mount the appliance on a place
where children can’t reach.
22. The light emitting by UVC lamp might cause aging effect. Once it is powered ON, please
keep away valuable things and dark color things from lamp. Long-time lighting exposure to
valuable and dark color things would cause the color to fade.
WARNING!
THE DISINFECTION LAMP EMITS UVC AND OZONE. DURING THE WORKING OF THE LAMP,
HUMAN AND ANIMAL MUST GET OUT FROM THE PLACE. AVOID LOOKING DIRECTLY INTO
THE LIGHT. AFTER STERILIZATION IT IS ADVISED TO VENTILATE THE PLACE FOR 20-30
MINUTES. THE LAMP EMITS OZONE, INTENSE EXPOSURE OF WHICH IS HARMFUL.
IN CASE OF ANY QUERY/ISSUE WITH THE PRODUCT, PLEASE REACH OUT TO US AT: SUPPORT@V-TAC.EU
FOR MORE PRODUCTS RANGE, INQUIRY PLEASE CONTACT OUR DISTRIBUTOR OR NEAREST DEALERS.
V-TAC EUROPE LTD. BULGARIA, PLOVDIV 4000, BUL.L.KARAVELOW 9B