LG MS-217SJ MICROWAVE OVEN

SERVICE MANUAL - Page 20

For MS-217SJ.

PDF File Manual, 34 pages, Read Online | Download pdf file

MS-217SJ photo
Loading ...
Loading ...
Loading ...
5-10
COMPONENTS TEST PROCEDURE RESULTS
RELAY 2
FAN MOTOR
(Wire leads removed)
TURNTABLE
MOTOR
(Wire leads removed)
Check for continuity of relay 2 with an
ohm-meter.
(Remove wire leads from relay 2 and
operate the unit.)
Measure the resistance.
(Ohm-meter scale: R x 1)
Measure the resistance.
(Ohm-meter scale: R x 1 )
POWER
LEVEL
1 4 sec 18 sec
2 6 sec 16 sec
3 8 sec 14 sec
4 10 sec 12 sec
5 12 sec 10 sec
6 14 sec 8 sec
7 16 sec 6 sec
8 18 sec 4 sec
9 20 sec 2 sec
10 22 sec 0 sec
Normal:
A: Approx. 85 ~ 100 ohm.
B: Approx. 10 ~ 25 ohm.
Abnormal: Infinite or several
ohm.
Normal: Approx.100~150 ohm
Abnormal: Infinite or several
ohm.
Relay 2
A
B
SENSOR 1) Disconnect sensor connector from
micom computer board.
2) Measure resistance terminal to terminal
(ohm meter scale: R X 1000)
Normal: Approximately
BK - RD: 5.1 Kohm
RD - WH: 2.1 Kohm
BK - WH: 2.1 Kohm
Abnormal: Infinite or several.
* Sensor cooking condition
1. Oven should be plugged in at
least 5 minutes before sensor
cooking.
2. Room temperature should not
exceed 95
°F .
3. Be sure the exterior of the
cooking container and the
interior of the oven are dry.
Wipe each off with paper towel.
4. The oven will not generate
microwave energy for the first
28 seconds of the sensor
cooking cycle.
NOTE : • A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED
WHEN THE UNIT IS SERVICED FOR ANY REASON.
• MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION.
• WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE
TO GRASP THE CONNECTOR, NOT THE WIRES.
RD
BK
WH
1
2
3
Loading ...
Loading ...
Loading ...