40
206-4137
Reference: b-LAN Setup & Overview
The control device at the head end, for example, an FMA-LG101 or a PCS100R, can control multiple TVs. When
the TV is first installed, it must be turned ON in order for the head end to be able to communicate with the
b-LAN. At this point, if it is desired for the b-LAN to always be powered, including while the TV is in Standby, set
Installer Menu item 118 POWER SAVINGS to 001.
If the embedded b-LAN, including the Pro:Centric data tuner, will not be used, enable maximum power savings
in both Standby and TV Power On Mode by setting Installer Menu item 118 POWER SAVINGS to 007. However,
note that this action will disable Pro:Centric operation.
Warning for LD650H/LD655H TVs: If an MPI card is installed, POWER SAVINGS must be set to 001.
See table below. (Also see note regarding MPI cards at the top of the page.)
POWER SAVINGS 32/37/42LD650H/LD655H MPI Slot
001 Supported
003 (default) Not Supported
007 Not Supported
POWER
SAVINGS
TV Power On State
TV Standby State
b-LAN Power
b-LAN Power
001 On On
003 (default) Off On
007 Off Off
The b-LAN module is internal to the TV. It allows the hotel/institution head end equipment to communicate, via
the institution’s RF distribution system, with the TV for configuration and control. The b-LAN module also com-
prises the data tuner required for Pro:Centric operation.
Note: MPI cards with b-LAN technology—LMT7Z5, LMT7Z7, LMT7Z9—are NOT supported on TVs in which the
b-LAN module is embedded.
Power to the b-LAN module is controlled by Installer Menu item 118 POWER SAVINGS. The default value is
003—the b-LAN module is only powered when the TV is turned ON. See chart below.