Faber AGIO36WH / 630006625 Agio Fluorescent

User Manual - Page 4

For AGIO36WH / 630006625.

PDF File Manual, 13 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Version 7/11 - Page 4
TOOLS NEEDED FOR INSTALLATION
• Saber Saw or Jig Saw
• Drill
• 1 1/4" Wood Drill Bit
• Pliers
• Phillips Screwdriver
• Flat Blade Screwdriver
• Wire Stripper or Utility Knife
• Metal Snips
• Measuring Tape or Ruler
• Level
• Pencil
• Caulking Gun
• Duct Tape
PARTS SUPPLIED FOR INSTALLATION
• 1 Backdraft Damper
• 4 Black Screws & 4 Silver Screws
• 1 Literature Package
PARTS NEEDED FOR INSTALLATION
• 2 Conduit Connectors
• Power Supply Cable
• 1 Wall or Roof Cap
All Metal Ductwork

Charcoal Filters
For non-vented installations only,
replace charcoal lters as needed
part # FILTER3
PLAN THE DUCTWORK
The Agio convertible rangehood is designed to offer wide
exibility of installations. The rangehood can be ducted
vertically or horizontally through a 3 1/4" X 10" rectangular
vent. The unit can also be installed in a ductless recirculating
conguration. FIGURES 1 and 2 show horizontal and vertical
duct installations for this rangehood.  shows the
exhaust opening for ductless installation.
HORIZONTAL
DUCTING

DUCTING
DUCTLESS
INSTALLATION
CALCULATE THE DUCTRUN LENGTH
The ductrun should not exceed 25 equivalent feet if ducted with the
required minimum of 3 1/4" by 10" rectangular duct. Calculate the
length of the ductwork by adding the equivalent feet in FIGURE 4
for each piece of duct in the system. An example is given in FIGURE
5. 
sure that there is a minimum 
elbows if more than one is used. Do not install two elbows
together.far away from

FIGURE 4
45˚ Elbow
90˚ Elbow
90˚ Flat Elbow
Wall Cap
3.0 feet
5.0 feet
12.0 feet
0.0 feet
9 Feet Straight Duct
2 - 90˚ Elbows
Wall Cap
Total System
9.0 feet
10.0 feet
0.0 feet
19.0 feet
FIGURE 5
PLAN THE DUCTWORK
First, determine which venting option will be used:
• Horizontal
• Vertical
• Ductless
For Horizontal and Vertical ducting, the ductwork cutout dimensions
are given in FIGURE 6. For ductless installations, read the section
discussing ductless installations before you make any cutouts or
modications to the rangehood. Ductless installations require
Charcoal Filters.
FIGURE 6
30" or 36" or 23 5/8" (60 cm)
30" or 36" or 23 5/8" (60 cm)
FIGURE 1
FIGURE 2

Pre-Planning Your Installation -
Important: The
recommended height to install this hood off the cooktop
is a minimum of 24" and a maximum of 30” for maximum
effectiveness. Also consult the cooktop manufacturer’s
recommendation.