CALIFORNIA CARB/SNAP DISCLOSURE For products manufactured after January, 1, 2019:
Retail food refrigeration equipment manufactured after January 1, 2019, designed to store
and display chilled goods for commercial sale, and that use HFC-134a/R134a refrigerant are
not for sale in California.
*This product uses eco-friendly hydrocarbon refrigerant and fully complies with California
CARB regulations. However, we are required by California Law to provide the previous
disclosure statement in every product sold in California.
This product does not use any refrigerants on the “List of Prohibited Substances.”
FOLLOW WARNING CALLOUTS BELOW ONLY WHEN APPLICABLE TO YOUR MODEL
Use two or more people to move and install the appliance. Failure to do so can result in
back or other injury.
To prevent overheating and fire hazard, remove all packaging before use, including the
tray at the bottom of the appliance.
When installing, leave at least 8" at the back of the unit.
To ensure proper ventilation for your appliance, the front of the unit must be completely
unobstructed. Choose a well-ventilated area with temperatures above 60°F (16°C) and
below 90°F (32°C). This unit must be installed in an area protected from the elements,
such as wind, rain, water spray or drips.
The appliance should not be located next to ovens, grills or other sources of high heat.
The appliance must be installed with all electrical, water and drain connections in
accordance with state and local codes. A standard electrical supply (115 V AC only, 60
Hz), properly grounded in accordance with the National Electrical Code and local codes
and ordinances, is required.
Do not kink or pinch the power supply cord of the appliance.
The size of the fuse (or circuit breaker) should be 15 amperes.
DANGER - Risk of fire or explosion. Flammable refrigerant used.
Do not use mechanical devices to defrost refrigerator. Do not
puncture refrigerant tubing.
To be repaired only by trained service personnel. Do not puncture
refrigerant tubing.
CAUTION - Risk of fire or explosion
Flammable refrigerant used. Consult repair manual/owner’s
guide before attempting to service this product. All safety
precautions must be followed.
Dispose of properly in accordance with federal or local
regulations. Flammable refrigerant used.
Risk of fire or explosion due to puncture of refrigerant tubing.
Follow handling instructions carefully. Flammable refrigerant
used.
CAUTION- Avoid obstructing any ventilation openings in the appliance
or in the enclosure when building-in.