D Series Air, Water or Remote User Manual
December 2014
Page 7
Water - Air or Water Cooled
The water supply for ice making must be cold, potable
water. There is a single 3 8” male are potable water
connection on the back panel. Water cooled models
also have a 3/8” FPT inlet connection for the water
cooled condenser. Chilled water can also be used for
this connection.
Backow
The design of the oat valve and reservoir prevents
potable water backow by means of a 1" air gap
between the reservoir's maximum water level and the
oat valve water inlet orice.
Drain
There is one ¾” FPT condensate drain tting at the
back of the cabinet. Water cooled models also have a
½” FPT discharge drain connection on the back panel.
Attach Tubing
Connect the potable water supply to the potable water
tting, 3/8” OD copper tubing or the equivalent is
recommended.
Water ltration is recommended. If there is an existing
lter, change the cartridge.
Connect the water cooled water supply to the
condenser inlet.
Note: Do NOT lter water to the water cooled
condenser circuit.
Drains - use rigid tubing: Connect the drain tube to the
condensate drain tting. Vent the drain.
Connect the water cooled condenser drain tube to the
condenser outlet. Do not vent this drain.
Do not Tee ice machine drains into the drain tube
from the ice storage bin or dispenser. Back ups
could contaminate and / or melt the ice in the bin or
dispenser. Be sure to vent the bin drain.
Follow all local and national codes for tubing, traps
and air gaps.
Water Inlet
Connection
Drain
Connection
Condensate
Drain Tube
Building Drain
Water Inlet
Connection
Drain
Connection
Condensate
Drain Tube
Condenser Inlet
Connection
Condenser
Drain Tube
Air Cooled or Remote Plumbing
Water Cooled Plumbing