Gas Connection
Hook-up$t o$the$gas$supply$line:$3/8”$SAE$(UNF$5/8”$-$18)$male$flare$connection.$A$
backup$wrench$must$be$used$when$tightening$gas$supply$fitt ing.$$All$completed$
connections$should$be$checked$for$leaks$with$a$non-corrosive$leak$detector$and/or$
soap$and$water$for$a$bubble$check.$
WARNING& &DO&NOT&US E& F LAME &T O& CHECK& FOR& GAS& LEAK S$
The$gas$supply$system$must$incorporate$a$pressure$regulator$to$maintain$a$supply $
pressure$of$not$more$than$12”$water$column$and$no$less$than$11”$water$column.$
(Max$setting)$$
Make$sure$the$refrigerator$and$any$other$high$BTU$appliances$on$your$line$are$
turned$on$when$checking$the$gas$pressure.$The$appliance$and$its$individual$shut-
off$valve$must$be$disconnected$from$the$gas$supply$piping$system$during$any$
pressure$testing$of$that$system$at$pressures$in$exc ess$of$½”$psig.$
$
In$case$detailed$instructions$on$the$installation$and$connection$of$the$gas$supply$
are$required,$contact$your$dealer$or$distributor.$
Leveling
Ensure$the$fridge$is$level$by$using$a$ 2ft$level.$This$is$ accomplished$ by$adjusting$ the$feet$ at$
the$front,$undern eath $the $fridge.$