8 www.brutepower.com
Operation
Step 2: Oil and Fuel
Fuel must meet these requirements:
Clean, fresh, unleaded fuel with a minimum of 87 octane.
Gasoline with an ethanol content up to 10% is acceptable.
E10
E15
NOTICE Do not mix oil in fuel or modify engine to run on
alternate fuels. Use of unapproved fuels could damage
engine and will not be covered under warranty.
See High Altitude for 5,000 ft. and above.
WARNING! Fuel and its vapors are extremely
flammable which could cause burns or fire
resulting in death or serious injury.
Do not refuel during operation.
Do not smoke during refueling.
Turn engine off and let it cool at least 2 minutes before
removing fuel cap.
Fill fuel tank outdoors. Keep fuel away from sparks, open
flames, pilot lights, heat, and other ignition sources.
Check fuel lines, tank, cap and fittings frequently for
cracks or leaks. Replace if necessary.
1. Move generator outdoors to a flat, level surface.
2. Clean area around oil fill and remove oil fill cap/dipstick.
3. Slowly pour contents of oil bottle into oil fill opening.
Checking oil level frequently, fill to full mark on dipstick.
NOTICE DO NOT screw in dipstick when checking oil level.
NOTICE Pause to permit oil to settle. Wipe dipstick clean
each time oil level is checked. DO NOT overfill.
4. Replace and fully tighten oil fill cap/dipstick.
5. Slowly remove fuel cap to relieve pressure in tank.
6. Slowly add unleaded fuel to fuel tank. Be careful not
to fill above bottom lip. This allows adequate space for
fuel expansion.
7. Install fuel cap and let any spilled fuel evaporate
before starting engine.
High Altitude
At altitudes over 5,000 ft. (1524 m), a minimum 85 octane
fuel is acceptable. To remain emissions compliant, high
altitude adjustment is required. Operation without this
adjustment will cause decreased performance, increased
fuel consumption,
and increased emissions.
See an authorized dealer for high altitude adjustment information.
Operation of the engine at altitudes below 2,500 ft. (762 m) with
the high altitude kit is not recommended.
Transporting
When transporting equipment with a vehicle or trailer, turn fuel
shutoff valve to off (0) position. Do not tip engine or equipment at
an angle which causes fuel to spill.
Step 3: Generator Start Up
Disconnect all electrical loads from the generator. Use the
following start instructions:
1. Make sure unit is outdoors on a level surface.
NOTICE Failure to operate the unit on a level surface may cause
the unit to shut down.
2. Turn the fuel valve to the on (I) position.
3. Push choke lever to choke ( ) position.
4. Set engine switch to on (I) position.
5. Grasp recoil handle and pull slowly until slight
resistance is felt. Then pull rapidly to start engine.
6. Slowly move choke lever to run ( ) position. If engine
falters, move choke lever to half choke position until
engine runs smoothly, and then to run ( ) position.
NOTICE If engine starts but fails to run, see Low Oil
Shutdown in Features and Controls.
Full
Fuel Valve
Choke Lever
Engine Switch