3.4
Wifi hotspot: factory setting is "0FF",
press > to enable wifi hotspot and switch
ON/OFF.The device can transmit data and receive
APP commands.The icon flickers when connected
on the main interface. After successful connection,
the icon displays normally.
3.5.1
The power down time is adjusted according to">"
and the power down time increases from 3 to 20
minutes (3-5-10-15-20), which is the so-called
stop time of the fan after shutdown, in order to
better drain the water.Factory set for 3 minutes.
(the other state of the fan is still 15 seconds.)
3.5.2
The screen displays when you press shut
down:
Indicates: the fan is closed after a few minutes,
and the standby page UNIT OFF is displayed after
the fan is closed.
3.6 3.7
Temp Units /Used for temperature scale
switching.Press the ">" button to switch ℉/,
after switch symbol of corresponding parts is also
changing.
MOISTURE CONTENT UNITSIt is used to
switch the unit of GPP value with moisture
content. Press > to switch the Ib or Kg, after
switch symbol of corresponding parts is also
changing.
3.8
"Humidistat Setpoint 00%":Used for setting dehumidification
mode humidity.Press ">" to set the humidity. The adjustment
range of humidity setting is between 25 and 80%.
Each key rises or falls 5%, which can be recycled.
When the setting is completed,do not operate for 5 seconds
and begin to take effect.(Otherwise, the compressor will be
shut down immediately after it is below ambient humidity at
the time of setting.) Humidity below 25 percents "CO" mode
recyclable.The main interface displays the set parameters.
4. Main interface frosting status display:
The machine will display this after defrost when running
When the machine is running normally, “Defrost
SHUTDOWN IN 06:00will occurs in the
interface after defrosting. Its defrost countdown
use seconds as units. This screen displays only
3 seconds. Displays the previous interface and
status after restoration.If it is the home screen,
the frost icon will flash.
When the user is operating in the submenu, the
machine is in the frosting state.At this point, the
frosting interface displays 3 seconds, and returns
to the submenu program in the background
countdown.When the user returns to the main
interface without any operation, the frosting state
is displayed in the main interface in the way of
icon flicker.
5. Compressor on waiting interface display
Compressor protection time not shown:
Compressor ready IN 03:00 indicates : That the
interface will be displayed when the compression is
in a protected state. (including power-on and shutdown,
the humidity rises immediately after the arrival of L0
HI, and the shutdown resumesimmediately after the
emergence of L0 HI).Displays the countdown in seconds.If the
above situation does not occur within 3 minutes, it is not
shown.
6 7
t
LB
Only applicable to app-controlled dehumidifier.