American Range ARR1060L 60 Inch Freestanding Professional Ga

User Manual - Page 11

For ARR1060L.

PDF File Manual, 22 pages, Read Online | Download pdf file

ARR1060L photo
Loading ...
Loading ...
Loading ...
INSTALLATION
STEP THREE: CONNECT GAS & ELECTRICAL SUPPLY
I. Connect the gas supply.
NOTE: Before placing appliance into operation, always check for gas leaks. This must be performed by your dealer, a qualied
licensed plumber, or gas service company
J. Connect the electrical supply.
F
A
B
C
BD
E
F
A. Gas pressure regulator.
B. Adapter (must have 1/2” male pipe thread).
C . Flexible connector.
D. Manual gas shut-off valve.
E. 3/4” or 1/2” gas supply.
F. Use pipe-joint compound.
To avoid risk of electrical shock, personal injury or death; leak testing of the appliance must be conducted
according to the manufacturer’s instructions. Before placing appliance in operation, always check for gas
leaks with soapy water solution.
DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS
DANGER
!
IMPORTANT - This appliance is equipped with a three-prong grounding plug for your protection against possible
electric shock hazard. Plug it only to a dedicated, grounded three-prong electrical outlet. It is the responsibility of the
customer to make sure the proper type of outlet is installed. Do not, under any circumstances, ground to a gas pipe.
DESIGNED & BUILT IN USA
PROFESSIONAL COOKING EQUIPMENT
13592 Desmond St., Pacoima, CA 91331 818.897.0808 tel 888.753.9898 toll free www.americanrange.com
10
WARNING
!
The electrical service in the building must be equipped with a properly grounded three-prong receptacle,
in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/
NFPA 70, or in Canada - to Canadian electrical codes, CSA C22.2.
DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THIS PLUG
I
J
Loading ...
Loading ...
Loading ...