TROUBLESHOOTING (Continued)
If the pump starts and stops too often:
1. Check for backflow of water from discharge hose/pipe. Install or replace check valve.
2. Check float switch for proper operation. Replace if necessary.
If the pump will not shut off:
1. Make sure switch drops to full down position. It may be obstructed.
2. Check for obstructions in piping.
If the pump runs and moves little or no water
1. Make sure check valve is installed in correct direction.
2. Check to insure discharge pipe is not plugged.
If you have any question or problems, call us first at 1-800-495-9278 or contact us on the web:
www.superiorpumpco.com
NOTICE
Height and/or piping restriction will reduce the pump output performance.
Whenever possible use the same or larger size pipe than the pump discharge for optimum
performance. Reducing the pipe size will not harm your pump; it will just slow the flow.
PERFORMANCE CHART
SPECIFICATIONS
Power supply requirements 120V, 60 Hz
Motor Continuous Duty, Capacitor Start
Amps 7.6
Horsepower ½ HP
Liquid Temperature Range 32° F - 120° F
Circuit Requirements 15 amp
Discharge Size 2”
Solids Handling 2”
Discharge Height above pumping level
0’ 5’ 10 15’ 20’ 25’
GPM 80 68 60 44 25 2
GPH 4800 4080 3600 2640 1500 300