GE - General Electric AZ95E18DAC GE Zoneline Cool/Electric Resistance Heat Vertical Air Conditioner 230/208 Volt

User Manual - Page 11

For AZ95E18DAC.

PDF File Manual, 12 pages, Read Online | Download pdf file

AZ95E18DAC photo
Loading ...
Loading ...
Loading ...
geappliances.com
11
SPECIFICATIONS
230-208 VOLTAGE
GE AZ95 SERIES - 230-208*
COOLING WITH ELECTRIC HEAT
AZ95E09DAC AZ95E12DAC AZ95E18DAC
Voltage 230-208 230-208 230-208
FEATURES
Cooling BTUH 9,200 11,500 17,400
EER (min.) 11.5 12.1 11.2
Cooling power (W) 795 940 1,550
Cooling current (A) 3.6 4.3 7. 3
Sensible Heat Ratio (SHR) 74% 73% 72%**
Dehumidification (pints per hour) 2.2 2.8 4.5**
Refrigerant R-410A R-410A R-410A
Indoor CFM (hi/lo) (0.1 ESP) 408/305 408/356 468/408
CASE DIMENSIONS
Width (in.) 23-5/8 23-5/8 23-5/8
Depth (in.) 24-1/8 24-1/8 24-1/8
Height (in.) 31-7/8 31-7/8 31 -7/8
Net weight (lbs.) 119 127 141
Approx. ship. weight (lbs.) 132 140 154
Clearances for front install (min.) 3" on all sides 3" on all sides 3" on all sides
Clearances for side install (min.)
5" to front
3" on sides
5" to front
3" on sides
5" to front
3" on sides
*230V Performance Data Listed
** 18K Dehum Rate and SHR data acquired using medium fan speed. All other models show low fan speed data.
GE AZ95 SERIES - 230-208*
HEAT PUMP WITH BACKUP ELECTRIC HEAT
AZ95H09DAC AZ95H12DAC AZ95H18DAC
Voltage 230-208 230-208 230-208
FEATURES
Cooling BTUH 8,900 11,300 17,000
EER (min.) 11.1 11.8 11.1
Cooling power (W) 800 955 1,525
Cooling current (A) 3.7 4.5 7.1
Sensible Heat Ratio (SHR) 76% 75% 71%**
Dehumidification
(pints per hour) 1.9 2.5 4.4**
Refrigerant R-410A R-410A R-410A
Indoor CFM (hi/lo) (0.1 ESP) 408/305 417/376 468/40 8
HEAT PUMP
Heating BTU 8,500 10,500 15,800
COP***(min.) 3.3 3.5 3.3
Heating power (W) 735 870 1,400
Heating current (A) 3.5 4.3 6.6
CASE DIMENSIONS
Width (in.) 23-5/8 23-5/8 23-5/8
Depth (in.) 24-1/8 24-1/8 24-1/8
Height (in.) 31-7/8 31-7/8 31-7/8
Net weight (lbs.) 122 128 142
Approx. ship. weight (lbs.) 135 141 155
Clearances for front install (min.) 3" on all sides 3" on all sides 3" on all sides
Clearances for side install (min.)
5" to front
3" on sides
5" to front
3" on sides
5" to front
3" on sides
*230V Performance Data Listed
** 18K Dehum Rate and SHR data acquired using medium fan speed. All other models show low fan speed data.
* **Coefficient of Performance
IMPORTANT NOTICE
Equipment used as a primary source for heating or cooling is an integral part of the building in which it is installed.
Proper application is essential for satisfactory performance over a wide range of operating conditions. It is
strongly recommended that a professional engineer determine proper application.
If this unit is a replacement unit, its specifications and performance may differ from those of the unit it is replacing.
For that reason, we again strongly recommend that a professional engineer determine proper application.
Loading ...