
ROOM
AIR
CONDITIONER
OWNER'S
MANUAL
AIRE
ACONDICIONADOR
MANUAL
DEL
PROPIETARIO
Please
read
the
operating
instructions
and
safety
precautions
carefully
and
thoroughly
before
installing
and
operating
your
room
air
conditioner.
MODEL,
MODELO:
HBLG1453E
Por
favor
lea
las
instrucciones
de
operacion
y
las
precauciones
de
seguridad
cuidadosa
y
totalmente
antes
de
instalar
y
operar
su
acondicionador
de
aire
de
ventana.
Manufactured
by
LG
Electronics

1.
Safety
Precautions
2.
Operating
Instructions
3.
Care
and
Maintenance
4.
Hardware
Installation
5.
Common
Issues
FOR
YOUR
RECORDS
Write the
model and
serial
numbers
here:
Model
#
Serial
#
You
can
find
them
on
a
label
on
the side
of
each
unit.
Dealer's
Name
Date
Purchased
Staple
your
receipt
to
this
page
in
the
event
you
need
it
to
prove
date
of
purchase
or
for
warranty
issues.
READ
THIS
MANUAL
Inside
you
will
find
many
helpful
hints
on
how
to
use
and
maintain
your
air
conditioner
properly.
Just
a
little
preventive
care
on
your
part
can
save
you
a
great
deal
of
time
and
money
over
the
life
of
your
air
conditioner.
You'll
find
many
answers
to
common
problems
in
the
chart
of
troubleshooting
tips.
If
you
review
our
chart
of
Troubleshooting
Tips
first,
you
may
not
need
to
call
for
service
at
all.
PRECAUTION
?
Contact
the
authorized
service
technician
for
repair
or
maintenance
of
this
unit.
?
Contact
the
installer
for
installation
of
this
unit.
?
The
air
conditioner
is
not
intended
for
use
by
young
children
or
invalids
without
supervision.
?
Young
children
should
be
supervised
to
ensure
that
they
do
not
play
with
the
air
conditioner.
?
When
the
power
cord
is
to
be
replaced,
replacement
work
shall
be
performed
by
authorized
personnel
only
using
only
genuine
replacement
parts.
?
Installation
work
must
be
performed
in
accordance
with
the
National
Electric
Code
by
qualified
and
authorized
personnel
only.

3
ENGLISH
Precautions
Safety
Precautions
To
prevent
injury
to
the
user
or
other
people
and
property
damage,
the
following
instructions
must
be
followed.
Incorrect
operation
due
to
ignoring
instruction
will
cause
harm
or
damage.
The
seriousness
is
classified
by
the
following
indications.
WARNING
CAUTION
This
symbol
indicates
the
possibility
of
death
or
serious
injury.
This
symbol
indicates
the
possibility
of
injury
or
damage
to
properties
only.
Meanings
of
symbols
used
in
this
manual
are
as
shown
below.
Be
sure
not
to
do.
Be
sure
to
follow
the
instruction.
WARNING
Installation
Always
install
the
expansion
panel(s).
?
No
installation
may
cause
fire
and
electric
shock
accident.
Do
not
place
the
power
cord
near a
heater.
?
It
may
cause
fire
and
electric
shock.
Do
not
use
the
power
cord
near
flammable
gas
or
combustibles
such
as
gasoline,
benzene,
thinner,
etc.
?
It
may
cause
explosion
or
fire.
Do
not
disassemble
or
modify
products.
?
It
may
cause
failure
and
electric
shock.
Gasolin

4
Operation
Plug
in
the
power
plug
properly.
?
Otherwise,
it
will
cause
electric
shock
or
fire
due
to
heat
generation
or
electric
shock.
Do
not
operate
or
stop
the
unit
by
inserting
or
pulling
out
the
power
plug.
?
It
will
cause
electric
shock
or
fire
due
to
heat
generation.
Do
not
damage
or
use
an
unspecified
power
cord.
?
It
will
cause
electric
shock
or
fire.
Do
not
modify
power
cord
length.
?
It
will
cause
electric
shock
or
fire
due
to
heat
generation.
Do
not
share
the
outlet
with
other
appliances.
?
It
will
cause
electric
shock
or
fire
due
to
heat
generation.
Always
plug
into
a
grounded
outlet.
?
No
grounding
may
cause
electric
shock
(See
Installation
Manual).
Unplug
the
unit
if
strange
sounds,
odors,
or
smoke
come
from
it.
?
Otherwise
it
may
cause
fire
and
electric
shock
accident.
Do
not
use
the
socket
if
it
is
loose
or
damaged.
?
It
may
cause
fire
and
electric
shock.
Do
not
operate
with
wet
hands
or
in
damp
environment.
?
It
will
cause
electric
shock.
ON

5
ENGLISH
Do
not
allow
water
to
run
into electric
parts.
?
It
will
cause
failure
of
machine
or
electric
shock.
Leave
the
door
closed
while
the
air
conditioner
is
running.
?
It
is
not
designed
to
cool
the
entire
house.
Ventilate
before
operating
air
conditioner
when
gas
goes
out.
?
It
may
cause
explosion,
fire,
and
burn.
Never
touch
the
metal
parts
of
the
unit
when
removing
the
filter.
?
They
are
sharp
and
may
cause
injury.
Do
not
block
the
inlet
or
outlet.
?
It
may
cause
failure
of
appliance
or
accident.
Ensure
that
the
outer
case
is
not
damaged
by
age
or
wear.
?
If
leaving
appliance
damaged,
there
is
concern
of
damage
due
to
the
falling
of
product.
Be
cautious
not
to
touch
the
sharp
edges
when
installing.
?
It
may
cause
injury.
Hold
the
plug
by
the
head
when
taking
it
out.
?
It
may
cause
electric
shock
and
damage.
Turn
off
the
main
power
switch
when
not
using
it
for
a
long
time.
?
Prevent
accidental
startup
and
the
possibility
of
injury.
CAUTION
Installation
Sharp
edges
Operation

6
Do
not
place
heavy
object
on
the
power
cord
and
take
care
so
that
the
cord
should
not
be
pressed.
?
There
is
danger
of
fire
or
electric
shock.
If
water
enters
the
product,
turn
off
the the
power
switch
of
the
main
body
of
appliance.
Contact
service
center
after
taking
the
power-plug
out
from
the
socket.
Do
not
clean
the
air
conditioner
with
water.
?
Water
may
enter
the
unit
and
degrade
the
insulation.
It
may
cause
an
electric
shock.
Turn
off
the
power
and
breaker
firstly
when
cleansing
the
unit.
?
Since
the
fan
rotates
at
high
speed
during
operation,
it
may
cause
injury.
Do
not
put
a
pet
or
house
plant
where
it
will
be
exposed
to
direct
air
flow.
?
This
could
injure
the
pet
or
plant.
Do
not
use
this
appliance
for
special
purposes
such
as
pets,
foods,
precision
machinery,
or
objects
of
art.
?
It
is
an
air
conditioner,
not
a
precision
refrigeration
system.
Always
insert
the
filter
securely.
Clean
it
every
two
weeks.
?
Operation
without
filters
will
cause
failure.
Use
a
soft
cloth
to
clean.
Do
not
use
wax,
thinner,
or
a
strong
detergent.
?
The
appearance
of
the
air
conditioner
may
deteriorate,
change
color,
or
develop
surface
flaws.
Do
not
drink
water
drained
from
air
conditioner.
/
Do
not
direct
airflow
at
room
occupants
only.
?
It
contains
containments
and
will
make
you
sick.
/
This
could
damage
your
health.
Wax
Thinner

7
ENGLISH
Prior
to
Operation
Safety
Precautions
Preparing
for
operation
Contact
an
installation
specialist
for
installation.
Plug
in
the
power
plug
properly.
Do
not
share
the
same
outlet
with
other
appliances
Do
not
use
an
extension
cord.
Do
not
start/stop
operation
by
plugging/unplugging
the
power
cord.
If
cord/plug
is
damaged,
replace
only
with
an
authorized
part.
6
5
4
3
2
1
Usage
Cleaning
and
maintenance
Do
not
use
water
to
clean
inside
the
air
conditioner.
Exposure
to
water
can
destroy
the
insulation,
leading
to
possible
electric
shock.
When
cleaning
the
unit,
first
make
sure
that
the
power
and
breaker
are
turned
off.
The
fan
rotates
at
a
very
high
speed
during
operation.
There
is
a
possibility
of
injury
if
the
unit's
power
is
accidentally
triggered
on
while
cleaning
inner
parts
of
the
unit.
2
1
Service
For
repair
and
maintenance,
contact
your
authorized
service
dealer.
Being
exposed
to
direct airflow
for
an
extended
period
of
time
could
be
hazardous
to
your
health.
Do
not
expose
occupants,
pets,
or
plants
to
direct airflow
for
extended
periods
of
time.
Due
to
the
possibility
of
oxygen
deficiency,
ventilate
the
room
when
using
together
with
stoves
or
other
heating
devices.
Do
not
use
this
air
conditioner
for
non-specified
special
purposes
(e.g.
preserving
precision
devices,
food,
pets,
plants,
and
art
objects).
Usage
in
such
a
manner
could
harm
such
property.
3
2
1

8
Power
Temp
Fan
Speed
Timer
Mode
1
2
3
4
5
'F
TIMER
POWER
MODE
TEMP
FAN
SPEED
F1
LOW
F2
MED
F3
HIGH
Dry
Timer
Fan
Energy
Saver
Cool
1
2
6
3
4
5
Remote
Control
Operations
Operating
Instructions
The
remote
control
and
control
panel
will
look
like
those
represented
in
the
following
pictures.

9
ENGLISH
Push
out
the
cover
on
the
back
of
the
remote
control
with
your
thumb
Pay
attention
to
polarity
and
insert
two
new
AAA
1.5V
batteries.
Reattach
the
cover.
:
Do
not
use
rechargeable
batteries.
Make
sure
that
both
batteries
are
new.
?
In
order
to
prevent
discharge,
remove
the
batteries
from
the
remote
control
if
the
air
conditioner
is
not
going
to
be
used
for
an
extended
period
of
time
Keep
the
remote
control
away
from
extremely
hot
or
humid
places.
To
maintain
optimal
operation
of
the
remote
control,
the
remote
sensor
should
not
be
exposed
to
direct
sunlight.
?
The
remote
control
can
be
mounted
on
a
wall
using
the
mountable
holder.
NOTICE
3
2
1
Inserting
the
Remote
Control
Batteries
POWER
Operation
starts
when
this
button
is
pressed
and
stops
when
you
press
the
button
again.
TEMPERATURE
CONTROL
The
thermostat
monitors
room
temperature
to
maintain
the
desired
temperature.
The
thermostat
can
be
set
between
60°F~86°F
(16°C~30°C).
The
unit
takes
an
average
of
30
minutes
to
adjust
the
room
temperature
by
1°F.
OPERATION
MODE
SELECTOR
Select
cooling
mode
to
cool
the
room.
Select
energy
saver
mode
for
energy
saving
operation.
Select
fan
mode
for
basic
ventilating
fan
operation.
Select
dry
mode
for
dry
operation.
FAN
SPEED SELECTOR
For
increased
power
while
cooling,
select
a
higher
fan
speed.
3
steps:
High
Low
Med
ON/OFF
TIMER
The
timer
can
be
set
to
start
and
stop
the
unit
in
hourly
increments
(up
to
12
hours).
REMOTE
CONTROL
SENSOR
6
5
4
3
2
1
Remote
Control
Operations
AUTO
RESTART
In
failure
of
electric
power,
the
unit
runs
as
previous
setting
operation.

10
OPEN
VENT
CLOSE
Part
A
Adjusting
the
Air
Flow
Direction
Operating
Instructions
Vent
Control
For
maximum
cooling
efficiency,
CLOSE
the
vent.
This
will
allow
internal
air
circulation.
OPEN
the
vent
to
discharge
stale
air.
Adjusting
the
Air
Flow
Direction
?
Recommended
orientation
of
louvers
Adjust
louvers
to
face
upwards
when
cooling
to
maximize
cooling
efficiency.
Airflow
can
be
adjusted
by
changing
the
direction
of
the
air
conditioner's
louvers.
This
can
also
increase
the
cooling
efficiency
of
the
air
conditioner.
:
Before
using
the
ventilation
feature,
position
the
vent
lever
straight
by
pulling
Part
A
out
and
snapping
it
into
place.
NOTICE
Adjusting
horizontal
air
flow
Adjusting
vertical
air
flow
?
Adjusting
Horizontal
Air
Flow
Direction
Adjusting
the
vertical
louvers
left
and
right
will
change
horizontal
airflow.
?
Adjusting
Vertical
Air
Flow
Direction
Adjusting
the
horizontal
vane
up
and
down
will
change
vertical
airflow.
The
vane
can
be
adjusted
by
nudging
the
vane
backward
or
forward.

11
ENGLISH
Drain
pipe
Drain
cap
Care
and
Maintenance
Care
and
Maintenance
Turn
the
power
off
and
unplug
the
power
plug
before
cleaning
the
air
conditioner.
Air
Filter
The
air
filter
behind
the
inlet
grille
should
be
checked
and
cleaned
at
least
once
every
2
weeks
(or
as
necessary)
to
maintain
optimal
performance
of
the
air
conditioner.
How
to
remove
the
air
filter
The
grille
may
be
opened
from
the
top
for
easy
maintenance
after
installation.
Open
the
inlet
grille
by
pulling
off
the
exposed
door
on
the
top
of
the
unit
(based
on
installation).
Pull
the tab
slightly
to
release
the
filter.
Pull
the
filter
in
the
same
direction
as
the
opening.
Clean
the
filter
with
warm,
soapy
water.
The
water
should
be
below
40°C
(104°F).
Rinse
off
and
gently
shake
off
excess
water
from
the
filter.
Let
it
dry
before
replaceing
it.
5
4
3
2
1
Drainage
The
base
pan
may
overflow
due
to
high
humidity.
To
drain
the
excess
water,
remove
the
drain
cap
from
the
back
of
the
unit
and
secure
the
drainpipe.
When
pressing
the
drainpipe
into
place,
apply
force
in
the
direction
away
from
the
fins
to
avoid
injuring
yourself.

12
CABINET
DRAIN
PAN
DRAIN
HOSE
SCREW
Take
the
drain
pan
which
is
located
in
the
air
discharge.
Remove
the
hole
rubber
from
the
base-pan
(for
some
models).
Install
the
drain
pan
to
the
right
corner
of
the
cabinet
with
4
(or
2)
screws.
Connect
the
drain
hose
of
3/5"
inside
diameter
to
the
outlet
located
at
the
bottom
of
the
drain
pan.You
can
purchase
the
drain
hose
or
tubing
locally
to
satisfy
your
particular
needs.
(Drain
hose
is
not
supplied).
4
3
2
1
The
air
conditioner
employs
a
proper
drain
method
whereby
the
condensed
water
(moisture
removed
from
the
air)
is
drained
to
the
outside.
In
very
humid
weather,
(and
for
reverse
cycle
models
in
the
reverse
mode)
excessive
condensate
water
removed
from
the
air
may
cause
some
water
to
collect.
To
remove
this
excess
water
you
can
install
the
drain
pan
as
detailed
below.
How
to
Attach
Drain
Pan

13
ENGLISH
4
1
2
3
13
11
14
12
7
10
B
A
6
5
8
15
9
Power
Cord
Power
Cord
Hardware
Installation
Hardware
Installation
Product
Features
1.
CABINET
2.
FRONT
GRILLE
3.
AIR
FILTER
4.
AIR
INTAKE
(INLET
GRILLE)
5.
AIR
DISCHARGE
6.
VERTICAL
AIR
DEFLECTOR
(HORIZONTAL
LOUVER)
7.
EVAPORATOR
8.
HORIZONTAL
AIR
DEFLECTOR
(VERTICAL
LOUVER)
9.
CONTROL
PANEL
10.
POWER
CORD
11.
COMPRESSOR
12.
BASE
PAN
13.
BRACE
14.
CONDENSER
15.
REMOTE
CONTROLLER
Installing
the
Power
cord
You
can
choose
between
two
methods
below
according
to
your
window
stool
shape
and
preference.
?
Fasten
the
stopper
using
2
screw
holes,
and
lead
out
the
power
cord
through
slit
"A".
?
Fasten
the
stopper
using
left
screw
hole,
and
rotate
properly
to
lead
the
power
cord
out
through
slit
"B".
Using
slit
"A"
Using
slit
"B"
CAUTION:
This
appliance
should
be
installed
in
accordance
with
national
wiring
regulations.
The
following
information
serves
acts
as
a
guide
to
help
to
explain
product
features.

14
About
1/2"
30"~60"
Awning
Cooled
air
Fence
Over
20"
Heat
radiation
29"
to
41"
18"
min.
Inner
sill
Offset
Window
Sash
Sill
Exterior
Interior
wall
29"
min.
(Without
frame
curtain)
How
to
Install
the
Unit
To
prevent
vibration
and
noise,
make
sure
the
unit
is
installed
securely
and
firmly.
Install
the
unit
where
the
sunlight
does
not
shine
directly
on
the
unit.
There
should
be
no
obstacles,
such
as
a
fence
and
wall,
within
20"
from
the
back
of
the
cabinet
because
it
will
prevent
heat
radiation
of
the
condenser.
Restriction
of
outside
air
will
greatly
reduce
the
cooling
efficiency
of
the
air
conditioner.
Install
the
unit
a
little
slanted
so
the
back
is
slightly
lower
than
the
front
(about
1/2").
This
will
force
condensed
water
to
flow
to
the
outside.
Install
the
unit
with
the
bottom
about
30"~60"
above
the
floor
level.
5
4
3
2
1
Window
Requirements
:
All
supporting
parts
should
be
secured
to firm
wood,
masonry,
or
metal.
?
This
unit
is
designed
for
installation
in
standard
double
hung
windows
with
actual
opening
widths
from
29"
to
41".
?
The
top
and
bottom
window
sash
must
open
sufficiently
to
allow
a
clear
vertical
opening
of
18"
from
the
bottom
of
the
upper
sash
to
the
window
stool.
NOTICE
CAUTION:
All
side
louvers
of
the
cabinet
must
remain
exposed
to
the
outside
of
the
structure.

15
ENGLISH
Installation
Kits
Contents
Suggested
Tool
Requirements
NO.
NAME
OF
PARTS
Q'TY
1
FRAME
CURTAIN
2
2
SUPPORT
BRACKET
2
3
SILL
BRACKET
2
4
LOCK
NUT
4
5
SCREW
(TYPE
A)
14
6
SCREW
(TYPE
B)
7
7
SCREW
(TYPE
C)
5
8
SCREW
(TYPE
D)
2
9
CARRIAGE
BOLT
2
10
FOAM
STRIP
1
11
FOAM
SEAL
1
12
WINDOW
LOCKING
BRACKET
1
13
DRAIN
PIPE
1
14
FRAME
GUIDE
2
15
FOAM-PE
1
PREPARATION
OF
CHASSIS
Remove
the
screws
which
fasten
the
cabinet
at
both
sides
and
at
the
back.
Slide
the
unit
from
the
cabinet
by
gripping
the
base
pan
handle
and
pulling
forward
while
bracing
the
cabinet.
Cut
the
window
sash
seal
to
the
proper
length.
Peel
off
the
backing
and
attach
the
Foam-Seal
to
the
underside
of
the
window
sash.
Remove
the
backing
from
the
top
upper
guide
Foam-PE
and
attach
it
to
the
bottom
of
the
Upper
Guide.
Attach
the
upper
guide
onto
the
top
of
the
cabinet
with
3
Type
A
screws
.
Insert
the
Frame
Guides
into
the
bottom
of
the
cabinet.
Insert
the
Frame
Curtain
into
the
Upper
Guide
and
Frame
Guides
.
Fasten
the
curtains
to
the
unit
with
10
Type
A
screws
.
8
7
6
5
4
3
2
1
SCREWDRIVER(Philips
and
Flatead),
RULER,
KNIFE,
HAMMER,
PENCIL,
LEVEL
11
15
(Type
A)
5
(Type
A)
Upper
Guide
Upper
Guide
1
2 3
4
5
6
78
9
10
11
14 12 13
15
5
14
Shipping
Screws

16
3
9
2
6
3
15
11
2
4
Fig.
1
Fig.
2
Fig.
3
Fig.
4
Support
Bracket
Lock
nut
Sill
Bracket
Carriage
Bolt
Front
angle
Window
stool
Window
sash
Upper
Guide
Cabinet
Foam
-Seal
Frame
curtain
Foam-PE
(Type
B)
Cabinet
Track
hole
Support
Bracket
Carriage
bolt
and
lock
nut
Machine
screw(Type
D)
and
lock
nut
Outer
edge
of
window
sill
Sill
bracket
Upper
Guide
Cabinet
Installation
Open
the
window.
Mark
a
line
on
the
center
of
the
window
stool
between
the
side
window
stop
moldings.
Loosely
attach
the
sill
bracket
to
the
support
bracket
using
the
carriage
bolt
and
the
lock
nut.
Attach
the
sill
bracket
to
the
window
sill
using
the
screws
(Type
B).
Carefully
place
the
cabinet
on
the
window
stool
and
align
the
center
mark
on
the
bottom
front
with
the
center
line
marked
window
stool.
Using
the
M-screw
and
the
lock
nut,
attach
the
support
bracket
to
the
cabinet
track
hole.
Use
the
first
track
hole
after
the
sill
bracket
on
the
outer
edge
of
the
window
sill.
Tighten
the
carriage
bolt
and
the
lock
nut.
Be
sure
the
cabinet
slants
outward.
.
Pull
the
bottom
window
sash
down
behind
the
Top
retainer
bar
until
they
meet.
:
1.
Do
not
pull
the
window
sash
down
so
tightly
that
the
movement
of
Frame
curtain
is
restricted.
Attach
the
cabinet
to
the
window
stool
by
driving
the
screws
(Type
B)
through
the
cabinet
into
window
stool.
2.
The
cabinet
should
be
installed
with
a
very
slight
tilt
downward
toward
the
outside.
NOTICE
4
3
2
1
CAUTION:
Do
not
drill
a
hole
in
the
bottom
pan.
The
unit
is
designed
to
operate
with
approximately
1/2"
of
water
in
bottom
pan.

17
ENGLISH
(Type
C)
6
7
Fig.
5
Fig.
6
Fig.
7
Fig.
8
Fig.
9
Screw(Type
B)
Front
Angle
Sash
track
Window
locking
bracket
Foam-Strip
Screw
Screw
Power
Cord
Pull
each
Frame
curtain
fully
to
each
window
sash
track,
and
pull
the
bottom
window
sash
down
behind
the
Top
retainer
bar
until
it
meets.
Attach
each
Frame
curtain
the
window
sash
by
using
screws
(Type
C.)
(See
Fig.
6)
Slide
the
unit
into
the
cabinet.(See
Fig.
7)
Cut
the
Foam-strip
to
the
proper
length
and
insert
between
the
upper
window
sash
and
the
lower
window
sash.(See
Fig.
8)
Attach
the
Window
locking
bracket
with
a
screw
(Type
C.)
(See
Fig.
9)
9
8
7
6
5
CAUTION:
For
security
purpose,
reinstall
screws(Type
A)
at
cabinet's
sides.

18
Fig.
10
Do
not
under
any
circumstances
cut
or
remove
the
grounding
prong
from
the
plug.
Line
Cord
Plug
Use
Wall
Receptacle
Power
Supply
Power
supply
cord
with
3-prong
grounding
plug
Standard
125V,
3-wire
grounding
receptacle
rated
15A,
125V
AC
Use
15
AMP,
time
delay
fuse
or
circuit
breaker.
Attach
the
front
grille
to
the
cabinet
by
inserting
the
tabs
on
the
grille
into
the
tabs
on
the
front
of
the
cabinet.
Push
the
grille
in
until
it
snaps
into
place.
(See
Fig.10)
Lift
the
inlet
grille
and
secure
it
with
a
screw
(Type
A)
through
the
front
grille.(See
Fig.
10)
Window
installation
of
room
air
conditioner
is
now
completed.
See
ELECTRICAL
DATA
for
attaching
power
cord
to
electrical
outlet.
12
11
10
Electrical
Data
Use
of
extension
cords
?
Because
of
potential
safety
hazards,
we
strongly
discourage
the
use
of
an
extension
cord.
However,
if
you
wish
to
use
an
extension
cord,
use
a
CSA
certified/UL-listed
3-wire
(grounding)
extension
cord,
rated
at
15A,
125V.

PREFERRED
METHOD
Ensure
proper
ground
exists
before
use
TEMPORARY METHOD
Adapter
plug
Receptacle
cover
Metal
screw
Fig.
11
Fig.
12
Electrical
Safety
IMPORTANT
(PLEASE
READ
CAREFULLY)
FOR
THE
USER'S
PERSONAL
SAFETY,
THIS
APPLIANCE
MUST
BE
PROPERLY
GROUNDED
The
power
cord
of
this
appliance
is
equipped
with
a
three-prong
(grounding)
plug.
Use
this
with
a
standard
three-slot
(grounding)
wall
power
outlet
(Fig.
11)
to
minimize
the
hazard
of
electric
shock.
The
customer
should
have
the
wall
receptacle
and
circuit
checked
by
a
qualified
electrician
to
make
sure
the
receptacle
is
properly
grounded.
DO
NOT
CUT
OR
REMOVE
THE
THIRD
(GROUND)
PRONG
FROM
THE
POWER
PLUG.
A.
SITUATIONS
WHEN
THE
APPLIANCE
WILL
BE
DISCONNECTED
OCCASIONALLY:
Because
of
potential
safety
hazards,
we
strongly
discourage
the
use
of
an
adapter
plug.
However,
if
you
wish
to
use
an
adapter,
a
TEMPORARY
CONNECTION
may
be
made.
Use
UL-listed
adapter,
available
from
most
local
hardware
stores
(Fig.
12).
The
large
slot
in
the
adapter
must
be
aligned
with
the
large
slot
in
the
receptacle
to
assure
a
proper
polarity
connection.
CAUTION:
Attaching
the
adapter
ground
terminal
to
the
wall
receptacle
cover
screw
does
not
ground
the
appliance
unless
the
cover
screw
is
metal,
and
not
insulated,
and
the
wall
receptacle
is
grounded
through
the
house
wiring.
The
customer
should
have
the
circuit
checked
by
a
qualified
electrician
to
make
sure
the
receptacle
is
properly
grounded.
Disconnect
the
power
cord
from
the
adapter,
using
one
hand
on
each.
Otherwise,
the
adapter
ground
terminal
might
break.
DO
NOT
USE
the
appliance
with
a
broken
adapter
plug.
B.
SITUATIONS
WHEN
THE
APPLIANCE
WILL
BE
DISCONNECTED
OFTEN.
Do
not
use
an
adapter
plug
in
these
situations.
Unplugging
the
power
cord
frequently
can
lead
to
an
eventual
breakage
of
the
ground
terminal.
The
wall
power
outlet
should
be
replaced
by
a
three-slot
(grounding)
outlet
instead.
USE
OF
EXTENSION
CORDS
Because
of
potential
safety
hazards,
we
strongly
discourage
the
use
of
an
extension
cord.
However,
if
you
wish
to
use
an
extension
cord,
use
a
CSA
certified/UL-listed
3-wire
(grounding)
extension
cord,
rated
at
15A,
125V.
ENGLISH
19

20
Common
Problems
and
Solutions
Common
Issues
Before
calling
for
service,
please
review
the
following
list
of
common
problems
and
solutions.
The
air
conditioner
is
operating
normally
when:
?
You
hear
a
pinging
noise.
This
is
caused
by
water
being
picked
up
by
the
condenser
on
rainy
days
or
in
highly
humid
conditions.
This
feature
is
designed
to
help
remove
moisture
in
the
air
and
improve
cooling
efficiency.
?
You
hear
the
thermostat
click.
This
is
caused
by
the
compressor
cycle
starting
and
stopping.
?
You
see
water
dripping
from
the
rear
of
the
unit.
Water
may
be
collected
in
the
base
pan
in
highly
humid
conditions
or
on
rainy
days.
This
water
overflows
and
drips
from
the
rear
of
the
unit.
?
You
hear
the
fan
running
while
the
compressor
is
silent.
This
is
a
normal
operational
feature.
The
air
conditioner
may
be
operating
abnormally
when:
Problem
Possible
Causes
What
To
Do
The
air
conditioner
is
unplugged
or
not
plugged
in
completely
The
fuse
is
blown/circuit
breaker
is
triggered
Power
failure.
Air
flow
is
restricted
The
THERMOSTAT
may
not
be
set
cool
enough
The
air
filter
is
dirty.
The
air
conditioner
was
just
turned
on.
Cold
air
is
escaping.
Cooling
coils
are
iced
up
The
cooling
coils
are
iced
over.
?
Make
sure
the
plug
is
completely
plugged
into
the
outlet
?
Check
the
fuse/circuit
breaker
box
and
replace
the
fuse
or
reset
the
breaker
?
In
the
event
of
a
power
failure,
set
the
power
control
to
OFF.
When
the
power
is
restored,
wait
3
minutes
to
restart
the
air
conditioner
to
prevent
the
compressor
from
overloading
?
Make
sure
there
are
no
curtains,
blinds,
furniture
or
other
obstacles
in
front
of
the
air
conditioner
?
Turn
the
knob
to
a
higher
setting.
The
highest
setting
provides
maximum
cooling
?
Clean
the
filter
at
least
every
2
weeks.
Refer
to
the
"Care
and
Maintenance"
section
(p.11)
of
the
manual.
?
After
the
air
conditioner
is
turned
on,
you
need
to
give
the
air
conditioner
some
time
to
cool
the
room.
?
Check
for
open
furnace
floor
resisters
and
cold
air
returns.
?
CLOSE
the
air
conditioner
vent
?
See
Ice
appears
on
the
air
conditioner
below
?
Ice
may
block
the
air
flow
and
obstruct
the
air
conditioner
from
properly
cooling
the
room.
Set
the
fan
at
MED
or
HIGH
while
setting
the
thermostat
at
1
or
2
until
the
ice
melts.
The
air
conditioner
does
not
operate
at
all
Air
conditioner
does
not
cool
Ice
appears
on
the
air
conditioner.
You
can
refer
to
the
Energy
Star
program
in
detail
at
"www.energystar.gov".

Memo

