GE JVB65SWW - 36" Telescopic Downdraft System

User Manual - Page 5

For JVB65SWW. Also, The document are for others GE - General Electric models: JVB34, JVB65, JVB35, JVB93, JVB64, JVB96

PDF File Manual, 12 pages, Read Online | Download pdf file

JVB65SWW photo
Loading ...
Loading ...
Loading ...
5
INSTALLATION INSTRUCTIONS
Before Starting Installation Check the
Following Requirements
This downdraft blower system is designed to be
used to exhaust smoke and odors when cooking
with all GE electric and sealed burner gas
cooktops (not approved for standard burner gas
cooktops). It can be mounted in either an island
or peninsula location.
Requirements for an approved installation
• 26 minimum cabinet depth
• 26 minimum from the back of the downdraft
to the front of the countertop, with
• 23
1
2
minimum FLAT countertop surface
• Plan the placement of the electrical outlet box
carefully. It should NOT be installed on the back
wall of the cabinet because it may interfere with
the downdraft. It should be installed on a side
wall or adjacent cabinet. Make sure it is within
reach of the unit’s 2 ft. long power cord and
conforms to all local codes.
Install a standard wiring box with a 3-pronged
outlet.
• Plan the location of the gas supply pipe (for
gas cooktops) carefully to avoid interference
with the downdraft installation.
Specifications
This unit can be easily installed following these
basic steps:
• Cut out the countertop opening.
• Install the downdraft in the cabinet.
• Connect the ductwork and electrical.
• Install the cooktop.
VOLTS AMPS CFM DUCT
120 4.0 500 3
1
4
X 10
Take Measurements
Refer to the cooktop installation instructions for
dimensions of cooktop, countertop cut-out, and
cabinet requirements.
The 30 models will fit in most 30 wide
cabinets and the 36 models will fit in most 36
wide cabinets.
To install a cooktop with this downdraft, the
cabinet depth must be 26 minimum.
A countertop with a raised lip may not allow
enough flat countertop for a proper installation.
Before starting installation review the following
pages carefully.
Cutout dimension and illustrations are given for
30 and 36 cooktops.
Flat counter
area
26
Minimum 26
Cabinet depth required
(continued next page)
Loading ...
Loading ...
Loading ...