Scotsman Mdt4f12

User Manual - Page 6

For MDT4F12.

PDF File Manual, 16 pages, Download pdf file

Loading ...
Loading ...
Loading ...
For The Plumber
Drains:
The dispenser requires a gravity drain. The pitch
on the drain tubes must be at least ¼ inch fall per
foot of horizontal run. On long horizontal runs, a
vent at the back of the cabinet will improve
draining, and is recommended.
There are two drains to connect: A sink drain, a
7
8
ID plastic tube; and the bin drain, a
5
8
ID plastic
tube. Install rigid tubing between the machine and
the building drain. Route the drains separately to
the building drain.
Water supply:
Connect cold, potable water to the machine. The
inlet water fitting is a 1/4" male flare located on a
wall inside the cabinet.
A hand valve near the
location is
recommended. A water
filter is also a good
idea.
Follow all local codes.
MDT3F & MDT4F User Manual
November 2008
Page 5
FOLLOW ALL APPLICABLE LOCAL, STATE
AND NATIONAL CODES
Strainer or
Filter
Water Inlet Fitting - 1/4"
Male Flare
(Inside Cabinet)
Sink Drain
Bin and Reservoir
Overflow Drains
Water Supply
Building Drain
(Typical)