CTEK ‎40-256 20A Off Grid Bundle - D250SA and Battery Monitor

User Manual - Page 3

For 40-256.

PDF File Manual, 12 pages, Read Online | Download pdf file

40-256 photo
Loading ...
Loading ...
EN•5
EN
FUNCTION INDICATIONS
D250SA Explanation
1
The service battery is being charged by the alternator.
2
The service battery is being charged by the solar panel.
3
The service battery is being charged by both the alternator and
solar panel.
4
The service battery is fully charged. The service battery is being
trickle charged by the solar panel.
5
Current saving mode, no charging in progress.
SMARTPASS 120 Explanation
1
SMARTPASS 120
+OUT
+OUT
+IN
Current from alternator to service battery and consumers.
Current from service battery to consumers.
2
SMARTPASS 120
+OUT
+OUT
+IN
Current from alternator to service battery and consumers.
3
SMARTPASS 120
+OUT
+OUT
+IN
Current from alternator to consumers. The service battery is
charged by the D250SA.
4
SMARTPASS 120
+OUT
+OUT
+IN
Trickle charging of the starter battery from the service battery.
CABLE AND FUSE RECOMMENDATIONS
UNIT CABLE
MIN. CABLE SIZE
FUSE
0.5 m
2 ft
1 m
3 ft.
2 m
6 ft.
5 m
15 ft.
10 m
30 ft.
+IN
+IN
4 mm
2
/
AWG12
4 mm
2
/
AWG12
4 mm
2
/
AWG12
6 mm
2
/
AWG10
10 mm
2
/
AWG8
30A
+OUT
4 mm
2
/
AWG12
6 mm
2
/
AWG10
10 mm
2
/
AWG8
30A
4 mm
2
/
AWG12
4 mm
2
/
AWG12
4 mm
2
/
AWG12
4 mm
2
/
AWG12
4 mm
2
/
AWG12
Connector plate*
4 mm
2
/
AWG12
6 mm
2
/
AWG10
10 mm
2
/
AWG8
10 mm
2
/
AWG8
10 mm
2
/
AWG8
+IN
35 mm
2
AWG2
35 mm
2
AWG2
35 mm
2
AWG2
50 mm
2
AWG1
50 mm
2
AWG1
300A
+OUT
+OUT
35 mm
2
AWG2
35 mm
2
AWG2
35 mm
2
AWG2
300A
*If the D250SA and SMARTPASS 120 are installed in different locations and the accompanying connector plate is
not used, please follow the recommendations in the table.
D250SA
SMARTPASS 120
Loading ...
Loading ...
Loading ...