Part Number: 000015430 Rev 02 5/20 165
HARVEST ASSIST AIR PUMP
FUNCTION
The air pump helps break the vacuum between the sheet
of ice and the evaporator which results in shorter harvest
cycles.
SPECIFICATIONS
115 Volt or 230 Volt - matches the ice machine voltage.
CHECK PROCEDURE
1. The air pump is wired in parallel with the harvest
valve - Verify the ice machine is in the harvest cycle
and the harvest valve is energized.
2. If there is voltage at the air pump connector, use
a volt ohm meter to verify there is no continuity
through the motor windings then replace motor.