PERFORMANCE DATA SHEET
Interior Water Filtration System
Model UKF8001AXX-750 Capacity 750 Gallons (2839 Liters)
System tested and certied by NSF International against NSF/ANSI
Standard 42, 53, 401 and CSA B483.1 for the reduction of
contaminants specied on the Performance Data Sheet.
This system has been tested according to NSF/ANSI Standards 42, 53, 401 and CSA B483.1 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system, as specied in NSF/ANSI Standards 42, 53, 401 and CSA B483.1.
Substance Reduction Aesthetic Effects Inuent Challenge Concentration Maximum Permissible Product Water
Concentration
Average% Reduction
Chlorine Taste/Odor 2.0 mg/L ± 10% 50% reduction 97.6%
Particulate Class I* At least 10,000 particles/mL 85% reduction 98.8%
Contaminant Reduction Inuent Challenge Concentration Maximum Permissible Product Water
Concentration
Average% Reduction
Lead***: @ pH 6.5 / @ pH 8.5 0.150 mg/L ± 10% 0.010 mg/L 99.3% / 99.3%
Mercury: @ pH 6.5 / @ pH 8.5 0.006 mg/L ± 10% 0.002 mg/L 95.1% / 95.0%
Asbestos 10
7
to 10
8
bers/L
††
>99% >99%
Cysts† 50,000/L min. >99.95% 99.99%
Turbidity 11 NTU ± 10% 0.5 NTU 98.1%
Atrazine 0.009 mg/L ± 10% 0.003 mg/L 94.4%
Benzene 0.015 mg/L ± 10% 0.005 mg/L 96.6%
Carbofuran 0.080 mg/L ± 10% 0.040 mg/L 86.8%
Lindane 0.002 mg/L ± 10% 0.0002 mg/L 98.8%
P-Dichlorobenzene 0.225 mg/L ± 10% 0.075 mg/L 99.7%
Tetrachloroethylene 0.015 mg/L ± 10% 0.005 mg/L 96.0%
Toxaphene 0.015 mg/L ± 10% 0.003 mg/L 93.8%
Atenolol 200 ± 20% 30 ng/L >95.9%
Endrin 0.006 mg/L± 10% 0.002 mg/L 96.7%
Ethylbenzene 2.1 mg/L ± 10% 0.7 mg/L 99.9%
o-Dichlorobenzene 1.8 mg/L± 10% 0.6 mg/L 99.9%
2,4 - D 0.210 mg/L ± 10% 0.07 mg/L 97%
Carbamazepine 1400 ± 20% 200 ng/L >98.6%
DEET 1400 ± 20% 200 ng/L >98.5%
Linuron 140 ± 20% 20 ng/L >96.8%
Meprobamate 400 ± 20% 60 ng/L 94.6%
Metolachor 1400 ± 20% 200 ng/L 98.3%
Trimethoprim 140 ± 20% 20 ng/L >96.4%
Bisphenol A 2000 ± 20% 300 ng/L 99.4%
Estrone 140 ± 20% 20 ng/L >96.7%
Nonylphenol 1400 ± 20% 200 ng/L >98.9%
Ibuprofen 400 ± 20% 60 ng/L 92.9%
Naproxen 140 ± 20% 20 ng/L >96.3%
Phenytoin 200 ± 20% 30 ng/L >94.8%
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (2.95 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
The compounds certied under NSF 401 have been deemed as “emerging compounds/incidental contaminants.” Emerging compounds/incidental contaminants are those
compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these compounds can affect the public acceptance/
perception of drinking water quality.
It is important that operational, maintenance, and lter replacement requirements
be carried out for the product to perform as advertised. Property damage can
occur if all instructions are not followed.
The disposable cartridge must be changed at least every 6 months.
Use replacement lter UKF8001, Part #EDR4RXD1/EDR4RXD1B. 2015
suggested retail price of $49.99 U.S.A./$49.95 Canada. Prices are subject to
change without notice.
The lter monitor system measures the amount of water that passes through the
lter and alerts you when it is time to replace the lter. To learn how to check the
water lter status, see “Using the Controls” or “Water Filtration System” in the
User Instructions or User Guide.
After changing the water lter, ush the water system. See “Water and Ice
Dispensers” or “Water Dispenser” in the User Instructions or User Guide.
These contaminants are not necessarily in your water supply. While testing was
performed under standard laboratory conditions, actual performance may vary.
The product is for cold water use only.
The water system must be installed in compliance with state and local laws and
regulations.
Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system. Systems certied for
cyst reduction may be used on disinfected waters that may contain lterable
cysts. EPA Est. No. 10350-MN-005.
Refer to the “Warranty” section (in the User Instructions or User Guide) for the
Manufacturer’s limited warranty, name and telephone number.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
City or Well
35 - 120 psi (241 - 827 kPa)
33° - 100°F (1° - 38°C)
0.78 gpm (2.95 L/min.) @ 60 psi
*Class I particle size: >0.5 to <1 um
***Compliant for Lead reduction requirements under NSF/ANSI Standard 53 as tested by Pace Analytical Services, Inc.
†Based on the use of Cryptosporidium parvum oocysts
††Fibers greater than 10 um in length
®
NSF is a registered trademark of NSF International.