Loading ...
Loading ...
Loading ...
11
INSTALLATION INSTRUCTIONS
Venting options
Attention should be given to ensure that any applicable regulations concerning the
discharge of exhaust air are fulfilled.
The cooker hood can be installed to operate with the exhaust air ducted externally from
the kitchen, or installed to operate with the exhaust air recirculating within the kitchen.
Ducted
For ducted installation it is recommended that 150mm diameter, rigid or semi-rigid
ducting is used. This will require a 160mm (min) round hole in the ceiling or wall.
Careshould be taken to position the hole correctly.
For optimal efficiency, use rigid or semi-rigid ducting for reduced noise and increased
airflow. Flexible ducting should only be used as a last resort (ie in difficult installations)
and if used, ensure that it is pulled tight.
Recirculating
To enable the product to operate with the air recirculating, please purchase a
recirculation diverter and carbon filters (refer to the ‘Parts and accessories’ section).
Therecirculation diverter is required to channel the air out the side vents at the top
ofthe flue and the carbon filters are required to remove odours.
Note: a ducting hole is not required in the wall or ceiling if the cooker hood is
installed to operate with exhaust air recirculating.
Loading ...
Loading ...
Loading ...