should be changed at three or six months according to your cooking habit. The
installation procedure of activated carbon filter is as below.
Remove the al filter.
Insert the carbon filter in the rectangular hole,fitting it over the motor.
After inserting the front edge of the carbon filter into the slot on the cooker hood.
Lower the back edge of the carbon filter, until it clicks into place at the rear of the
rectangular hole. Raise the two fixing bars, until they are horizontal over the
carbon filter.
Place the Al. filter back to position.
Apply reverse procedure to uninstall the carbon filter.
NOTE:
Make sure the filter is securely locked. Otherwise, it would loosen and cause
dangerous.
When activated carbon filter attached, the suction power will be lowered.
BULB REPLACEMENT
The bulb must be replaced by the manufacturer, its
service agent or similarly qualified persons.
Always switch off the electricity supply before
carrying out any operations on the appliance. When
handling bulb, make sure it is completely cool down
before any direct contact to hands.
When handling globes hold with a cloth or gloves to
ensure perspiration does not come in contact with
the globe as this can reduce the life of the globe.
LED LIGHTS:
• Switch the unit off and pull out the plug first.
• Wait until the light bulb is cooled down before replacement.
• Remove the front part with the aid of screwdriver.
Pull out the LED light carefully and replace with the same type and rated LED light
(2*2W LSD-B1 LED light)
• Replace the front part back to the unit with screwdriver.
ILCOS D code for this lamp is: DBR-2/65-H-64
LED modules, self- ballasted round lamp
Max wattage: 2 W
Voltage range: AC 220-240V
Dimensions: