7
TYPE I CYLINDER CONNECTIONS:
If the large black thermally sensitive coupling nut is exposed to temperatures above 115°
- 150°C, it will soften and allow the regulator probe to disengage from the cylinder valve,
thereby shutting off the flow of gas. Should this occur: do not attempt to reconnect the
nut. Remove the entire regulator assembly and replace it with a new one (see parts list).
The cause of the excessive heat should be determined and corrected before operating
your grill again. The regulator probe also contains a flow-sensing element, which will limit
the flow of gas to the regulator to a manageable amount (10 cubic feet per hour) in the
event of a hose or regulator failure, or a leak.
If it is evident that the flow-limiting device has activated, the cause of the excessive flow
should be determined and corrected before using your grill again.
NOTE: Improper lighting procedures can cause the flow-limiting device to activate,
resulting in reduced heat output. If this is suspected, shut off all burner controls
and cylinder valve, and carefully repeat lighting instructions step by step. Do not
remove the nut and probe and do not attempt to connect to anything other than a
mating Type I (Q.C.C.1) cylinder valve.
Never connect a propane gas grill to an unregulated propane gas supply or other gas.
Do not attempt to alter the hose or regulator in any way.
Do not allow the hose to come in contact with any hot surfaces of the charbroiler.
Visually inspect the entire length of the hose assembly before each use for any
evidence of damage (cuts, cracks, burns) or excessive wear. If found, replace the
assembly before using your charbroiler. Only a hose assembly as specified in the parts
list for your charbroiler should be used.
The connection fitting must be protected when disconnected from the propane
cylinder. If the fitting is allowed to drag on the ground, damage to the fitting may occur
resulting in leaks or an incomplete connection. Dirt could also enter the small inlet
hole, blocking gas flow completely.
NATURAL GAS AND FIXED LP MODELS:
RE: HOSES
Crown Verity Inc. charbroilers that are equipped for use with natural gas or fixed LP
systems require care and attention to the hose.
Inspect the hose, clean quick-connect coupling, and keep protected.
Always disconnect hose at quick-connect coupling when storing charbroiler.
The gas supply hose must be a minimum of 10-ft. (3.1 m) and must be equipped with
a shut-off valve, and must be installed by a certified technician.
The appliance must be disconnected from the gas supply piping during any pressure
testing of the system at test pressures in excess of 1/2 PSIG (3.5 kPa).
The outlet pressure setting for the pressure regulator provided with the appliance is
4.0” water column for natural gas.
10” water column for propane.