ADDITIONAL THINGS YOU SHOULD KNOW
Now that you have mastered the operating procedure, here are more features in your control that you should become familiar with.
The "Cool" circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly.
This prevents overheating of the compressor and possible circuit breaker tripping. The fan will continue
to run during this time.
There is a 2-Second delay for the compressor shutting down when selecting FAN ONLY. This is to cover the possibility of having
to roll through to select another mode.
After a power outage, the unit will memorize the last setting and return the unit to the same setting once power is restored.
The control will maintain the set temperature within 2 degrees Fahrenheit, between 60°F and 90°F degrees.
TO TURN UNIT OFF:
Note: After the unit is turned off, the light on the display
will gradually fade away in 3 seconds. The unit will always
return to “eco” mode and “auto” fan speed setting when it
is turned on again.
YOU WILL SEE:
DO THIS:
PRESS
ON/OFF BUTTON
After 60 seconds of control inactivity the display and indicator lights will turn off. Press any button on the control panel or remote
control and the display will resume. Please note that if the unit is in eco mode and the set temperature has been reached the unit
may appear off. However, the unit is on and will continue to sample the air every 10 minutes. To confirm, press any button on the
control panel or remote control to illuminate the display to show unit in eco mode.