(b) Make the following safety checks on all ovens to be
serviced before activating the magnetron or other
microwave source, and make repairs as necessary:
(1) interlock operation,
(2) proper door closing,
(3) seal and sealing surfaces (arcing, wear, and other
damage),
(4) damage to or loosening of hinges and latches,
(5) evidence of dropping or abuse.
(c) Before turning on microwave power for any service test
or inspection within the microwave generating
compartments, check the magnetron, wave guide or
transmission line, and cavity for proper alignment, integrity,
and connection.
(d) Any defective or misadjusted components in the
interlock, monitor, door seal, and microwave generation
and transmission systems shall be repaired, replaced, or
adjusted by procedures described in this manual before the
oven is released to the owner.
(e) A microwave leakage check to verify compliance with
the Federal Performance Standard should be performed on
each oven prior to release to the owner.
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an
electrical short circuit, grounding reduces the risk of electric
shock by providing an escape wire for the electric current.
This appliance is equipped with a cord having a grounding
wire with a grounding plug. The plug must be plugged into
an outlet that is properly installed and grounded.
WARNING:
Improper use of the grounding can result in a risk of electric
shock.
Consult a qualified electrician or serviceman if the
grounding instructions are not completely understood, or if
doubt exists as to whether the appliance is properly
grounded, and:
Do not use an extension cord. If the power supply cord
is too short, have a qualified electrician or serviceman
install an outlet near the appliance.