5
Temperature sensor short circuit, open circuit protection function
No matter in what mode, the temperature sensor appears short circuit or open
circuit, digital screen displays "E1" or "E2" and constantly flicker, while any key
operation is invalid and the buzzer rings 10 times.
Safety protection
In the start state, when the room temperature TH is above 12F, close all
outputs system, The digital screen displays "FF" and flashes 1 time per second
at a frequency of 75 times, press any key will not work, only the power down to
exit the protection.
Tip-over switch
As a safety measure, the unit will shut off automatically if it is
knocked over. Should this occur, simply turn the heater off and stand it back up
to a regular upright posit ion, then switch it back on.
ECO energy saving function
Select the ECO energy saving gear, electric heater according to the ambient
temperature and the temperature setting of the machine to do comparison,
select the appropriate gear operation to achieve the purpose of saving energy.
Remote controller
Use of the remote controller: the key functions are basically the same as the
body operation panel.