MAINTENANCE
Regular maintenance is important for optimal
performance and to reduce wear. Inspect and properly
tighten all parts each time the hybrid trainer is used.
Replace any worn parts immediately.
To clean the hybrid trainer, use a damp cloth and a
small amount of mild soap. IMPORTANT: To avoid
damage to the console, keep liquids away from
the console and keep the console out of direct
sunlight.
CONSOLE TROUBLESHOOTING
Most console problems are the result of low batteries.
To replace the batteries, see assembly step 12 on
page 12.
If the console does not display your heart rate when
you use the handgrip heart rate monitor, see step 5 on
page 20.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted.
To adjust the
reed switch,
first remove the
two M4 x 16mm
Screws (84) from
the Rear Access
Cover (26), and
then remove the
Rear Access
Cover.
Next, locate the Reed Switch (60). Slightly loosen the
two M4 x 16mm Screws (84).
Next, rotate the Large Pulley (48) until a Pulley Magnet
(93) is aligned with the Reed Switch (60). Slide the
Reed Switch slightly toward or away from the Pulley
Magnet. Then, retighten the M4 x 16mm Screws (84).
Rotate the Large Pulley (48) for a moment. Repeat
these actions until the console displays correct
feedback.
When the reed switch is correctly adjusted, reattach
the rear access cover.
84