Car Refrigerator Operation
▲Car battery protection voltage reference
Built-in ECO electronic control module can automatically monitor the car battery voltage. Before
power consumption affects the normal ignition of the car, car refrigerator will automatically
disconnect power, to ensure that the car battery power will not be consumed too low and affect
the normal ignition of the car.
Voltage
12V DC
24V DC
Factory default voltage protection level sets to H Mode
High mode Medium Mode Low mode
11.3V OFF, 12.5V ON 10.1V OFF, 11.4V ON 9.6V OFF, 10.9V ON
24.6V OFF, 26V ON 22.3V OFF, 23.7V ON 21.3V OFF, 22.7V ON
Note: When the car refrigerator connects to the power and starts, ON or OFF refers to the ON or
OFF of the compressor.
▲Parts schematic
① Compressor cooling hole
② Fuse
③ Power interface
④ Three-level switch for battery protection
⑤ Handle
⑥ Digital touch screen control panel
⑦ Seal rubber ring
⑧ Refrigerator cabinet