Dacor DOP48M96DPS Contemporary 48" Stainless Steel Dual-Fuel Liquid Propane Steam Range

User Manual - Page 31

For DOP48M96DPS.

PDF File Manual, 68 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
English 31
Installation requirements
Gas requirements
Provide adequate gas supply.
The installation of this appliance must conform with local codes or, in the absence of local
codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
The cooktop of this range is designed to operate at a manifold pressure of 5 in (13 cm) of
water column on natural gas.
Be certain that the appliance being installed is correct for the gas service provided
(natural gas).
When checking for proper operation of the regulator, the inlet pressure must be at least 1
in (2.5 cm) greater than the operating (manifold) pressure as given.
GAS SUPPLY PRESSURE REQUIREMENTS*
Gas Type Minimum Manifold Pressure Minimum Gas Supply Pressure**
Natural Gas 5” Water Column 6” Water Column
* The gas supply pressure for testing the regulator setting shall be at least 1 inch water
column (249 Pa) above the specified manifold pressure.
** Maximum gas supply pressure for all models: 1/2 psi.
Install_NY9900M_PRORANGE_DOP48M96DLM_DA_DG68-00936A-00_EN+MES+CFR.indb 31 2017-05-12  7:36:47
Loading ...
Loading ...
Loading ...