E01 LONG FREEZE
Freeze time exceeds 35 minutes for 3 consecutive freeze
cycles.
Possible cause checklist
Improper Installation
• Refer to “Installation/Visual Inspection Checklist” on
page 108
Water System
• Dirty/defective water level probe
• Low water pressure (20 psig min.)
• High water pressure (80 psig max.)
• High water temperature (90°F/32.2°C max.)
• Clogged water distribution tube
• Dirty/defective water fill valve
• Dirty/defective water dump valve
• Defective water pump
• Loss of water from sump area
Electrical System
• Low incoming voltage
• Ice thickness probe out of adjustment
• Harvest cycle not initiated electrically
• Contactor not energizing
• Compressor electrically non-operational
• Defective fan cycling control
• Defective fan motor
Miscellaneous
• Non-Manitowoc components
• Improper refrigerant charge
• Defective head pressure control
• Defective harvest valve
• Defective compressor