ELECTRICAL CONNECTION
Cookers can be presented with or without enrgy cable. Cable
connection should be done by Autorited service according to
following instructions.
The electrical connection must be made according to the
standards and regulations in force. Before making the electrical
connection, check the following:
•Is the capacity of the electrical connections and
safety fuses in
the building sufficient to cope with the load of the appliance?
(Check with the adhesive info label)
•Does the electricity supply line have an earth connection
conforming with the standards in force? A proper earth connection
must exist in your home. If there is not a proper earth
connection at
your home, please apply to an authorized technician to deal with
this problem.
•Is the socket or the multi-pole switch at a easily reachable point
after the installation of the appliance?
•A plug conforming to standards should be connected to the mains
cable and the cable should be inserted
into a safe socket.
•A multi-pole switch must be used between the appliance and the
electricity line if a direct electrical connection to the appliance is
required. (It must comply with standards and be appropriate for
the load)
The green-yellow ground cable must not be interrupted by a
switch. The brown phase
cable (from the “L" coded connector of
the oven) must always be connected to the phase line of the
mains.
•The power line must be positioned so that it is not exposed to
temperatures higher than 50° C.
•When the power cable must be changed, a cable with a cross
section appropriate
to the indicated power must be used. The
green-yellow ground cable should be approximately 2 cm longer
than phase and neutral cables.
•Check the heaters by switching them on for 3 minutes, after
having completed the connection.
•The manufacturer will not accept responsibility for damages
arising due to non-compliance with the
safety standards.
Cable box connection types
1- Monophase connection 2- Three-phase connection
Attention: A poor clamping can draw away risks dangerous
heating at the level of the cable feeding
Fuse
Cable - Section
Cable - Type
Monophase
220-240 V~
Three-phase
380-415V3N~
25 A3 x 16 A
2
3 G 2.5 mm
H05VV-F
ou H05RR-F
L1 : Phase
shunt 1-2 and
shunt 2-3
N : Neutral
shunt 4-5
T Earth
1 Phase
2 Phase
3 Phase
5 Neutral
shunt 4-5
T Earth
2
5 G 1.5 mm
H05VV-F
ou H05RR-F
COOKERS WITHOUT ENERGY CABLE COOKERS WITH ENERGY CABLE
•Connection is exclusively envisaged under tensions of 220-240V
Between phases or between phases and neutral.
•Connect 10/16 amperes to an outlet.
Neutral
Ground cable (Green-Yellow)
Phase cable