Troubleshooting
INDICATOR LEDS ON CHARGING STATION
LED STATUS MEANING ACTION
Green On Boundary wire and Charging station OK No action required.
Blue Flashing Boundary wire broken or not connected Check and repair boundary wire.
Red Flashing Electronic fault in charging station or power supply Unit Please contact your dealer
This section also presents some symptoms that can guide you if the mower does not work as expected.
INDICATOR LEDS ON MOWER
LED STATUS MEANING ACTION
1. Operating
(Green)
Flashing Recovery mode Place the robot in charging station with a
mobile with the GreenGuide App close to the
mower for software update of mower. This can
take up to 1 hour until the green LED to stop
flashing. If LED doesn’t stop flash then restart
the robot outside the CS and try again.
On Mower in operation mode (charging, parked in Charging
station, paused, mowing or searching)
Off Mower stopped with Stop button on mower, safety key in
Disabled position, mower in error state or mower waiting
for PIN code.
2. Connectivity
(Blue)
Flashing Mower not ready for Bluetooth connection If mower stopped with error the mower need
to be restarted with the Start button to allow
Bluetooth connection again
On Mower ready for Bluetooth connection with Mobile App
Off Mower not in ”Power on mode
3. Security
(Yellow)
Flashing PIN code authorization required ... via Mobile App.
Off No pin required No action required
4. Error
(Red)
Flashing Mower stopped with error Check the reason for the error and then restart
by pressing the Start button on the mower.