Table of contents

  • Mastercode
  • Troubleshooting: Door Jamming and Door Handing
  • Troubleshooting: Keypad
  • Troubleshooting: Battery
  • Battery FAQ

Enabling and Setting the Mastercode

  • Programming timeout: If no button is pressed for fi ve seconds, the system will time out and you will need to restart the procedure.
  • Keep door open. Press and HOLD the Program button until the keypad flashes green (about 5 seconds).
  • Enter new Mastercode.
  • Press Lock button once.
  • Re-enter Mastercode.
  • Press Lock button once.
  • Make sure switch #3 is on, and press the Program button once. If you hear three beeps and see the keypad fl ash green three times, the Mastercode is enabled.
  • Note: The lock will time out after fi ve seconds.

Adding User Codes with the Mastercode Enabled

The procedure for adding user codes is different when the Mastercode is enabled. For instuctions on how to add user codes when the Mastercode is disabled, see the Installation and User Guide that came with your lock.

  • Keep door open. Press the Program button once. The keypad will fl ash green and you will hear three beeps.
  • Enter Mastercode.
  • Press Lock button once.
  • Press the Program button the number of times that corresponds to the user code position being programmed. Example: If programming the third code, press the button three times.
  • Enter new user code.
  • Press Lock button once.
  • While the door is open and locked, test the user code to make sure it unlocks the door.

Disabling and Deleting the Mastercode

  • Keep door open. Press and HOLD the Program button until the keypad flashes green (about 5 seconds).
  • Press Lock button once.
  • Enter Mastercode.
  • Press Lock button once.
  • Re-enter Mastercode.
  • Press Lock button once.
  • Make sure switch #3 is on, and press the Program button once. If you don’t immediately hear three beeps and see the keypad fl ash green three times, the Mastercode is disabled.

The Status LED is solid red after the door handing process.

  • The lock interior is not mounted perpendicular to the ground.Remount lock interior assembly as illustrated in the Installation Guide.
  • The hole in the door is misaligned. Disassemble the lock, and reinstall it without the adapter ring on the exterior side of the door.
  • The latch is installed upside down. See page 8.
  • The battery level is too low. This is indicated by the keypad fl ashing red three times with three beeps. Use a fresh set of batteries, and perform the door handing process again.
  • The latch and strike are misaligned, causing the latch to bind. If you have not already done so, perform the door handing process while the door is open. If it is successful only when the door is open, the latch and strike are not aligned as they should be. Ensure door preparation is in accordance with the door drilling instructions, available online.


Newest Added: 99140-027 91550-030 92580-002 97300-829 99090-022

Tags: Kwikset Tools - Home Improvement Use Manual, Kwikset 99090 Manual, Kwikset Smart Code Manual, Kwikset EspaƱol, Kwikset, Kwikset Electronic Deadbolt Installation, Kwikset Z Wave Deadbolt Manual

Kwikset 99090-018 | Pages: 13 | Created on: 2015-03-23 | File type: PDF | Filename: 85595273_99090-022.pdf | Size: 919.33 KB | Language: English | Other documents: 2 files.

Download User Manual

Product Infomation and Reviews - 99090-018 photo

99090 018 Photo

View more photos

T: @manualsFile

https://manualsFile.com

Kwikset 99090-018 Questions and Answers