4
PROBLEMS
PUMPDOESNOTRUN
PUMPRUNSBUTDOES
NOTDELIVERWATER
PUMPRUNSBUTONLY
DELIVERSASMALL
AMOUNTOFWATER
FUSEBLOWSOR
CIRCUITBREAKER
TRIPSWHEN
PUMPSTARTS
MOTORRUNSFORA
SHORTTIME,THEN
STOPS
POSSIBLE CAUSES/SOLUTIONS
Line circuit breaker is o, or fuse is blown or loose
Pump cord is not making contact in receptacle.
If all of the above are OK, then the motor could be malfunctioning.
Discharge shut-o valve (if used) may be closed.
Impeller or volute openings are fully or partially clogged.
Remove pump and clean.
Pump is air-locked. Start and stop several times by plugging and
unplugging cord. Check for clogged vent hole in pump case.
Inlet holes in pump base are clogged. Remove pump and clean the
openings.
Vertical pumping distance is too high. Reduce distance or change the
discharge ttings of the pump.
Pump is air-locked. Start and stop several times by plugging in and
unplugging cord.
Vertical pumping distance is too high. Reduce distance or change the
discharge tting of the pump. Inlet holes in pump base are clogged.
Remove pump and clean the strainer and openings.
Impeller or volute openings are fully or partially clogged.
Remove pump and clean.
Pump impeller is partially clogged with tar or paint, causing motor to
run slow and overload. Remove pump and clean.
Pump impeller is partially clogged causing motor to run slow and
overload. Remove pump and clean.
Motor stator may be defective.
Fuse size or circuit breaker may be too small. (must be 15 amps).
Impeller or volute opening are fully or partially clogged.
Remove pump and clean .
Inlet holes in pump base are clogged. Remove pump and clean the
openings.
Pump impeller is partially clogged causing motor to run slow and
overload. Remove pump and clean.
Motor stator may be defective.
Impeller or volute openings are fully or partially clogged.
Remove pump and clean. Also clean the strainer if one is installed.
ELECTRICAL PRECAUTIONS
Before servicing a pump, always shut o the main power breaker and
then unplug the pump. Make sure you are not standing in water and are
wearing insulated protective sole shoes, under ooded conditions. Contact your local electric
company or a qualied licensed electrician for disconnecting electrical service prior to pump
removal
TROUBLE SHOOTING CHECKLIST (Caution: shut off power to pump)
Loading ...
Loading ...