Loading ...
Loading ...
Loading ...
3
The appliance must be placed in a room without sources of ignition (for example open
flames, an operating gas appliance or an operating electric heater).
R290 refrigerant gas complies with European environmental directives.
R290 has a low GWP (Global Warming Potential) of 3.
The CD12PRO-LE contains about 60g of R290 refrigerant gas.
The CD20PRO-LE contains about 75g of R290 refrigerant gas.
Do not use or store the CD20PRO-LE in an unventilated space with an area smaller
than 4.1m
2
per unit.
Do not use or store the CD12PRO-LE in an unventilated space with an area smaller
than 2.6m
2
per unit.
If the appliance is installed, used or stored in an unventilated room, the room must be
such as to prevent stagnation of possible leaks of refrigerant gas as there could be a
danger of fire or explosion should the refrigerant come into contact with electric
heaters, stoves or other sources of ignition.
Refrigerant gas may be odourless.
Do not use the product and contact the retailer for advice, if damage has occurred to
the unit which may have compromised the refrigerant system.
Any repairs or maintenance must only be carried out on the unit by a suitably qualified
engineer. Before opening and servicing the unit, the authorized engineer must be in
possession of a copy of the manufacturer’s service manual and must follow the safety
information contained within it to ensure all hazards are minimized.
The refrigerant system should not be perforated or punctured.
Do not place the unit next to heat sources (e.g. electrical fires, fireplaces, etc.)
Avoid mishandling the dehumidifier. Dropping, throwing the unit can cause damage to
its internals and increases the risks of operating it.
Do not store or use gasoline, petrol, paint, solvents or other flammable vapours or
liquids in the vicinity of this dehumidifier or any other appliance.
This dehumidifier must not be used in spaces where there is a high concentration of
gases, solvent or other volatile organic compounds; in very dusty environments; in any
domestic, commercial or industrial environment where the air composition is
flammable.
ENERGY SAVING AND UNIT SAFETY PROTECTION TIPS
Do not cover or restrict the airflow from the outlet or inlet grills. Do not operate and
follow troubleshoot procedure if the self-opening louvres do not open on power on.
For maximum performance, the minimum distance from a wall or objects should be 20
cm
Keep the filters or grills of the unit clean. Under normal conditions, filters or grills
should only need cleaning once every three weeks (approximately).
Since the filters remove airborne particles, more frequent cleaning may be necessary,
depending on the air quality. Vacuum both mesh and optional carbon filters and wash
the mesh filters with hot soapy water and dry them before placing them back in the
unit.
Loading ...
Loading ...
Loading ...